FR1DQ1-B Infrared Forehead Thermometer Distributed by: Microlife USA, Inc. 1617 Gulf to Bay Blvd.,Floor 2 Clearwater,FL 33755,UNITED STATES Phone: (727)-442-5353 www.microlifeusa.
8 ○ 12 ○ 13 ○ 17 ○ 21 ○ 25 ○ 10 ○ 9 ○ 11 ○ 14 ○ 15 ○ 18 ○ 22 ○ 16 ○ 19 ○ 23 ○ 20 ○ 24 ○ 26 ○ 27 ○
1 Measuring sensor ○ 2 Tracking light ○ 3 Display ○ 4 START/IO button ○ 5 MEMO button ○ 6 MODE ○ 7 Battery compartment cover ○ 8 All segments displayed ○ 9 Ready for measuring ○ ⑩Start the measurement ⑪Measurement complete 12 Body mode ○ 13 Object mode ○ 14 Low battery indicator ○ 15 Changing between Celsius and Fahrenheit ○ 16 Recall mode ○ 17 Recall the last 30 readings ○ ⑱Measured temperature too high ⑲Measured temperature too low 20 Ambient temperature too high ○ 21 Ambient temperature too low ○ 22 Erro
of any measurement. This Microlife thermometer is intended for measurement and monitoring not only the temperature of forehead of human body, but also the temperature of object. This thermometer has been clinically tested and proven to be safe and accurate when used in accordance to the operating instruction manual. Please read through these instructions carefully in order for you to understand all functions and safety information.
- Notes - Wireless communication interference 11. Error Messages 12. Cleaning and Disinfecting 13. Battery Replacement 14. Guarantee 15. Technical Specifications 16. www.microlife.com 1. The Advantages of this Thermometer Measures in a matter of seconds The innovative infrared technology allows the measurement without even touching the object. This guarantees safe and sanitary measurements within seconds.
Guidance system for self-measurement A blue tracking light shows the user that the device is at the right distance and ready to take a measurement. Bluetooth function This device connects to the «Microlife Connected Health+» App by using Bluetooth®4.2 and enables monitoring of temperature 2. Important Safety Instructions • Follow instructions for use. This document provides important product operation and safety information regarding this device.
® WARNING: The measurement results given by this device is not a diagnosis. It is not replacing the need for the consultation of a physician, especially if not matching the patient’s symptoms. Do not rely on the measurement result only, always consider other potentially occurring symptoms and the patient’s feedback. Calling a doctor or an ambulance is advised if needed. 3. How this Thermometer measures Temperature This thermometer measures infrared energy radiated from the forehead as well as objects.
6 button to confirm the years’ setting, then move to month setting. select year (21~40), then Press “MODE” ○ 6 button to confirm the month setting. then 5 button to select month (1~12), then press “MODE” ○ Press “MEMO” ○ 2. move to day setting 6 button to confirm the day setting. then move to 5 button to select day (1~31), Press “MODE” ○ Press “MEMO” ○ 3. next setting 4. Follow the previously mentioned instructions to set the day, hours, and minutes. 4 , the date and time are set and the time is 5.
○ ○ 1. Press the START/IO button 4 . The display 3 is activated to show all segments for 1second. ○ 2. A flashing «°C»/«°F» icon, the blinking blue tracking light 2 and a beep indicate that the device is ready to take a measurement ○ 10 . ○ 3. Press the MODE button 6 to switch between 3S and 1S body mode. 4. Remove any hair, sweat or dirt from the forehead before measuring to ensure the accuracy of the readings. 5.
automatically switch off after approx. 30seconds. NOTE: Patients and thermometer should stay in similar room condition for at least 30 minutes. • Don't take a measurement while or immediately after nursing a baby. • Don't use the thermometer in high humidity environments. • Patients should not drink, eat or exercise before/while taking the measurement. • Don't move the measurement device from the measuring area before hearing the termination beep.
This thermometer can recall the last 30 readings with a record of both time and date. ○ ○ • Recall mode16: Press the MEMO button 5 to enter recall mode when the power is off or in measuring mode. The memory icon «M» will display. ○ ○ • Reading the last reading 17 : Press and release the MEMO button 5 to recall the last reading. Number «1» and «M» are displayed. ○ • Pressing and releasing the MEMO button 5 after the last 30 readings have been recalled will resume the above sequence from reading.
If no message showed on App to confirm which patient log the data should be assigned to, please record the temperature data showed on FR1DQ1-B into the App manually or takes a new measurement and start Transfer Data step from 1 to 6 again. Bluetooth® Icon Indicator The Bluetooth® icon indicator on your device, located in the middle right portion of the display, is designed to provide information about the connection between your device and smartphone.
○ Flat battery indicator 24 : If only «battery» icon is shown on the display, the batteries should be replaced immediately. 12. Cleaning and Disinfecting Use an alcohol swab or cotton tissue moistened with alcohol (70% Isopropyl) to clean the thermometer casing and the measuring sensor. Ensure that no liquid enters the interior of the device. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the device in water or other cleaning liquids.
Acoustic: The unit is turned on and ready for the measurement: 1 short beep. Complete the measurement: 1 long beep (1 sec.) if the reading is less than 37.5 °C / 99.5 °F, 10 short «beep» sounds, if the reading is equal to or greater than 37.5 °C / 99.5 °F. System error or malfunction: 3 short «bi» sounds. Memory: 30 readings recall in the memory mode with a record of both time and date. Backlight: The display light will be GREEN for 5 seconds, when a measurement is completed with reading less than 37.
FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to the product are not approved by Microlife USA and could void the user's authority to operate the equipment under FCC jurisdiction.
Appendix Guidance and manufacturer’s declaration – electromagnetic emissions The model FR1DQ1-B is intended for use in the electromagnetic environment specified below. The customer or the user of the model FR1DQ1-B should assure that it is used in such an environment. Emissions RF emissions CISPR 11 RF emissions CISPR 11 Compliance Group 1 Electromagnetic environment-- guidance The model FR1DQ1-B uses RF energy only for its internal function.
Guidance and manufacturer’s declaration – electromagnetic immunity The model FR1DQ1-B is intended for use in the electromagnetic environment specified below. The customer or the user of the model FR1DQ1-B should assure that it is used in such an environment. Compliance level Electromagnetic environment --guidance ±8 kV contact ±15 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
Guidance and manufacturer’s declaration – electromagnetic immunity The model FR1DQ1-B is intended for use in the electromagnetic environment specified below. The customer or the user of the model FR1DQ1-B should assure that it is used in such an environment.
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
Recommended separation distances between portable and mobile RF communications equipment and the model FR1DQ1-B The model FR1DQ1-B is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.