Datasheet

Table Of Contents
© 2009 Microchip Technology Inc. DS39689F-page 337
PIC18F2221/2321/4221/4321 FAMILY
27.2 DC Characteristics: Power-Down and Supply Current
PIC18F2221/2321/4221/4321 (Industrial)
PIC18LF2221/2321/4221/4321 (Industrial)
PIC18LF2221/2321/4221/4321
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
PIC18F2221/2321/4221/4321
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Typ Max Units Conditions
Power-Down Current (I
PD)
(1)
PIC18LF2X21/4X21 0.5 0.7 μA -40°C
V
DD = 2.0V
(Sleep mode)
0.5 0.7 μA +25°C
0.5 1.7 μA +85°C
PIC18LF2X21/4X21 0.6 0.9 μA-40°C
V
DD = 3.0V
(Sleep mode)
0.6 0.9 μA +25°C
0.6 1.9 μA +85°C
All Devices 0.9 2.0 μA-40°C
V
DD = 5.0V
(Sleep mode)
0.9 2.0 μA +25°C
0.9 6.5 μA +85°C
Extended Devices Only 7.5 70 μA +125°C
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured
with the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS, and all features that
add delta current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin
loading and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have
an impact on the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD or VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: Low-power, Timer1 oscillator is selected unless otherwise indicated, where LPT1OSC (CONFIG3H<2>) = 1.
4: BOR and HLVD enable internal band gap reference. With both modules enabled, current consumption will be less
than the sum of both specifications.
5: When operation below -10°C is expected, use T1OSC High-Power mode, where LPT1OSC (CONFIG3H<2>) = 0.