Thank you for purchasing VS100 Impedance Matching Sliding
Speaker Volume Control. This product was manufactured with
the highest quality components and designed to deliver superior
performance.
Features:
The in-wall impedance protected volume controls were designed for
fast and easy installation in new construction and existing homes, offices
and commercial buildings. Packaged with the volume control you will find
three different color inserts. Removal and installation is carefully
accomplished by depressing and releasing the rear tabs.
The removable PCB wiring connectors accepts up to 14 gauge wire
and allows you to pre-wire your system during new construction before
the drywall stage, reducing the risk of damage to the unit. The
connectors make installation fast after construction. These stereo
controls feature 12 steps of attenuation.
Speci ications:
Power Handling: 100 Watts per channel max
Input/Output Wire Up to 14 ga. (compression quick connects)
Specications:
Impedance Protection: Protects up to 16 pairs of 8 ohm speakers
Mounting Conguration: Standard single duplex electrical box
Dimensions:
4-1/8" H x 1-5/8" W x 3" D (depth in wall 2-3/4")
Setting the Proper Impedance:
Use the chart to the right to determine the proper jumper setting for
your applications.
NOTE: Make sure that you select the proper jumper setting for both
right and left channels.
Speaker
Ohms X1 X2 X4 X8
8 2 Pair 3-4 Pair 5-8 Pair 9-16 Pair
4 1 Pair 2 Pair 3-4 Pair 5-8 Pair
Jumper Settings For 4Ω (Per Channel) Impedance At Amplier
IMPEDANCE CHART
The total number of speakers listed is for both Left and Right Channels (Pairs)
Jumper Settings For 8Ω (Per Channel) Impedance At Amplier
Speaker
Ohms X1 X2 X4 X8
8 1 Pair 2 Pair 3-4 Pair 5-8 Pair
4 - 1 Pair 2 Pair 3-4 Pair