Specifications

Appendices TS790+ & TS900+ Installation Manual
Quick Reference Engineers Menus
Engineers Menu 1
key Options Page
1
Program Panel Outputs
1 = Panel Output 1 (relay)
2 = Panel Output 2 (-ve)
3 = Panel Output 3 (+ve)
25
2
Program Digicom Outputs
1 = Channel 1 5 = Channel 5
2 = Channel 2 6 = Channel 6
3 = Channel 3 7 = Channel 7
4 = Channel 4 8 = Channel 8
25
3
Program Digicom Channels
1 = Channel 1 5 = Channel 5
2 = Channel 2 6 = Channel 6
3 = Channel 3 7 = Channel 7
4 = Channel 4 8 = Channel 8
25
4
Program Circuits & Attributes
Circuit Types Circuit Attributes
0 = Not Used 1 = Access
1 = Night 2 = D Knock
2 = 24 Hour 3 = Test
3 = PA Silent 4 = Omit
4 = PA Audible 5 = Reset
5 = Fire 6 = Flagged
6 = Auxiliary 7 = Entry
7 = Final Exit 8 = Chime
8 = Exit Term. Keyswitch Attributes
9 = Keyswitch F, A, B, C = wards
A = PSU - Battery L = Lockset
B = PSU - Fuse M = Momentary
C = PSU - Power I = Inverted
28
5
System Timers
00 = Test Call At 15 = Acc. Code Dur.
01 = No Rearms 16 = Modem Rings
02 = Settle Time 17 = C.I.D Alarms
03 = Pset Com Dly 18 = Ward Menu Dur.
04 = Exit time 19 = Test Call
05 = Entry Time 20 = Confirmation Time
06 = Bell Dur. 21 = P.Set Codes
07 = Bell Dly 22 = Line Fault Dly
08 = Double Knock 23 = AC Off Delay
09 = Test Time 24 = No. Rem Resets
10 = 2nd Entry 25 = Monitor Dur.
11 = Service Time 26 = Activity Dur.
12 = Payment Time 27 = P.Set Entry
13 = PSet Bell Delay 28 = Abort Delay
14 = Courtesy Dur
30
6
Setting Modes
0 = Full Set 1 = Final Exit
A = Part Set A 2 = Exit Terminator
B = Part Set B 3 = Timed Exit
C = Part Set C 4 = Instant
5 = Deferred
6 = Lockset
33
7
System Printout
34
8
Remote Reset Algorithm
Enter Algorithm number 004 - 199.
34
key Options Page
9
System Configuration
No. Yes No
00 = Bell is an SAB Bell is an SCB
01 = User 1 Limited User 1 Unlimited
02 = Fire Signals All Fire Signals Set
03 = Silent 24hr Ccts Audible 24hr Ccts
04 = Enable Duress Disable Duress
05 = PA Silent PA Audible
06 = Set with LF Can’t Set with LF
07 = User Reset Engineer Reset
08 = Tamp. User. Reset Tamp. Eng Reset
09 = Hi-Sec Engineer Lo-Sec Engineer
10 = OMs Minic OMs alarms
11 = Do Battery Test No Battery Test
12 = F.Exit Is Night F.Exit is Normal
13 = Audible T.Swicth Silent T.Switch
14 = Show P.Set Info Show Time Only
15 = Ans Phone defeat. Normal Answer
16 = Set with AC Off No Set with AC Off
17 = Loud Chime Normal Chime
18 = Invert O/P 1 Normal O/P 1
19 = Invert Digi O/Ps Normal Digi O/Ps
20 = Online Keypad No Online Keypad
21 = Restore PID PID Alarms Only
22 = User Authorised No Authorisation
23 = Mimic Alm & Flt Mimic Alarm Only
24 = Sndrs on Confirm Sndr on first alarm
25 = Bell on Confirm Bell on first alarm
26 = Confirm after Entry No conf after Entry
27 = Entry conf after 2 cct After 1 cct
28 = Confirmation on Confirmation off
29 = Entry kpd locked Entry kpd free
30 = Tamp as burg Tamp as tamp
31 = Unconf Usr Rst Unconf Eng Reset
32 = Keypad PA On Keypad PA Off
34
0
Go To User Menu 1
1 = Bell Test
2 = Walk Test
3 = Remote Reset
4 = Change Passcode
5 = Enable Chime
6 = Omit 24hr Group
7 = Omit Circuits
8 = Silent Set
9 = View Activity Count
0 = Full Set
A = Part Set A
B = Part Set B
C = Part Set C
37
B
View Location Text
38
C
Relearn
38