Specifications

Engineer’s Menu 2 TS790+ & TS900+ Installation Manual
View Circuits [2.1]
Each detection circuit may be viewed to
ascertain its status. The circuit status conditions
and resistance are shown below:
Status Response Normal Min. Max.
Healthy None
2.2 K 54 4.1K
Active Alarm
6.9 K 4.1 K 54 K
Tamper Tamper
54 K
Shorted Alarm
0 0 53
View Circuits Flowchart
Set System Time [2.2]
The system time is displayed in a 24hr format on
all remote keypads and is also used to time
stamp events in the system event log.
Set System Time Flowchart
Set System Date [2.3]
The system date is displayed in a
day/date/month format on LCD remote
keypads. it is also used to provide date stamps
for events in the system log.
Set System Date Flowchart
Change Passcode [2.4]
This option allows the engineer to change their
passcode. The default passcode is 1234 but
the installation engineer should change this to
their own personal 4 digit passcode.
Change Passcode Flowchart