Specifications

TS790+ & TS900+ Installation Manual Engineer’s Menu 1
02 Fire Signals all
When programmed as “Yes” fire alarm
activations are signalled to the ARC at all
times. When programmed as “No” fire alarm
activations are signalled to the ARC only
when the system is full set. (Default = Yes)
03 Silent 24hr Circuits
When programmed as “Yes” 24hr circuit are
silent. When programmed as “No” 24hr
circuits are audible. (Default = No)
04 Enable Duress
When programmed as “Yes” the reversal of
the first two digits on any passcode will
generate a duress alarm. When
programmed as “No” the reversal of the first
two digits on any passcode will NOT
generate a duress alarm. (Default = No)
05 PA Silent
When programmed as “Yes” PA’s activated
by pressing keys 1&3 on the remote keypad
will be silent. When programmed as “No”
PA’s activated by pressing keys 1&3 on the
remote keypad will be audible. (Default =
Yes)
06 Set with Line Fault
When programmed as “Yes” the system can
be set with a telephone line fault, however
the user will be asked to confirm this at the
time of setting. When programmed as “No
the system cannot be set with a telephone
line fault. (Default = Yes)
07 User Reset
When programmed as “Yes" alarms can be
reset by the user. When programmed as
”No" and alarm confirmation is disabled
then alarms can only be reset by the
engineer or via remote reset. Note that even
though user reset is disabled, while alarm
confirmation is enabled users can reset the
system after an unconfirmed alarm. (Default
= Yes)
08 Tamper User Reset
When programmed as “Yes" the user can
reset daytime tamper alarms. When
programmed as ”No" only the engineer can
reset daytime tamper alarms. (Default =
Yes)
09 High Security Engineer
When programmed as “Yes" the engineer
must enter his passcode and remote reset
number to gain access to engineer's menu
1. When programmed as ”No" only the
engineer's passcode is required to access
engineer's menu 1. (Default = No)
10 O/M’s Mimic Circuits
When programmed as “Yes" the output
modules mimic circuit activations. When
programmed as ”No" output modules give
circuit alarm indication. (Default = Yes)
11 Do Battery Test
When programmed as "Yes" the control
panel battery and any monitored PSU
batteries are tested every hour and when
exiting the engineer's mode. When
programmed as "No" the control panel
battery and any monitored PSU batteries are
not tested. (Default = No)
12 F.Exit is Night
When programmed as “Yes" final exit circuits
change to night circuits when the system is
part set. When programmed as ”No" final
exit circuits remain as final exit circuits when
the system is part set. (Default = No)
13 Audible Time Switch
When programmed as “Yes" the internal
sounder will activate when any of the time
switched outputs are active. When
programmed as ”No" the time switched
outputs remain silent. (Default = No)
14 Show Part Set Information (LED Keypads)
When programmed as “Yes" the display will
alternate between showing the time and
wards that are set when the system is part
set. When programmed as ”No" the display
will always show the time when the system is
part set. (Default = Yes)
15 Answer Phone Defeat
For use with the DC58M to allow
downloading to be carried out on telephone
line with answer phones. When programmed
as "Yes" Answer Phone Defeat is enabled.
(Default = No)
16 Set with AC Off
When programmed as “Yes” the system can
be set with no mains power. When
programmed as “No” the system cannot be
set with no mains power. (Default = Yes)