User Manual

INSTALLATION INSTRUCTIONS
13
© 2019 The Legacy Companies
Crescent Ice Maker Instruction Manual
Cutout Width
Minimum Flange
Mounting Area
Minimum Flange
Mounting Area
Cutout
Height
Cutout Dept
h
See Electrical
Specifications
for Power Supply
Filler Panel ˄Not Provided by Orien˅-
Needed to attach Mounting Flange on Unit
14-1/4"
(362 mm)
Flush to Cabinet (FTC)
or No Flanges
24-5/8"
(626 mm
)
16-1/2"
(420 mm)
5/8"
(16 mm)
4"
(102 mm)
7"
(178 mm)
Preferred location
for water line and
electrical outlet is
in adjacent
cabinet.
3/4"
(18 mm)
3/4"
(18 mm)
Cutout Width
Minimum Flange
Mounting Area
Minimum Flange
Mounting Area
Cutout
Height
See Electrical
Specifications
for Power Supply
Filler Panel ˄Not Provided by Orien˅-
Needed to attach Mounting Flange on Unit
15-1/8"
(384 mm)
Flush to Door (FTD)
18-3/8"
(466 mm)
5/8"
(16 mm)
4"
(102 mm)
7"
(178 mm)
Preferred location
for water line and
electrical outlet is
in adjacent
cabinet.
24-5/8"
(626 mm
)
Cutout Depth
3/4"
(18 mm)
3/4"
(18 mm)
A built-in installation requires 2” (5 cm) or more behind the unit for water line and plug clearance for
proper operation. Built-in units are designed for zero clearance at the top and each side of the unit.
Fan-forced condenser cooling is used. This requires air circulation through the lower section of the
unit.
NOTICE
If rubber feet are removed from the bottom of the unit, the mounting screws must be reinstalled
into the bottom of the cabinet to avoid damage to components mounted to the base pan.
The air path for exhaust and fresh air intake must be unrestricted! Recirculation between fresh
air intake and exhaust air must be prevented.
• Anyrestrictionofairoworventilationwilldisruptnormaloperationoftheunit,resultingin
damage components, and voids warranty.
Connect to potable water supply only.