Datasheet

MAX8526/MAX8527/MAX8528
1.425V to 3.6V Input, 2A,
0.2V Dropout LDO Regulators
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(Circuit of Figure 1: V
IN
= +1.8V, V
OUT
= +1.5V, EN = IN, I
OUT
= 2mA, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 1)
Note 1: Specifications to T
A
= -40°C are guaranteed by design, not production tested.
Note 2: Measurements at high current are pulse tested, such that the junction temperature is ambient temperature. Minimum supply
voltage for output accuracy must be at least 1.425V.
PARAMETER CONDITIONS
MIN TYP MAX
UNITS
GND
V
IN
= 3.6V, V
OUT
= 3V, I
OUT
= 20mA
440
GND Supply Current
Dropout, V
IN
= 3.6V, V
FB
= 480mV
500 800
µA
GND Shutdown Current V
IN
= 3.6V, EN = GND 0.5 50 µA
POK (MAX8527 Only)
FB high
540 550 560
Power-OK Threshold
V
FB
moving out of regulation,
V
HYS
= 10mV, IN = 1.425V to 3.6V
FB low
440 450 460
mV
POK Output Voltage Low V
FB
= 0.4V or 0.6V, I
POK
= 2mA 25
200
mV
POK Output Current High V
POK
= 3.6V
0.001
A
POK Fault Delay Time From FB to POK 25 50
100
µs
POR (MAX8528 Only)
Power-On Reset Threshold V
FB
falling, V
HYS
= 10mV, V
IN
= 1.425V to 3.6V
440 450 460
mV
POR Output Voltage Low V
FB
= 0.4V or 0.6V, I
POR
= 2mA 25
200
mV
POR Output Current High V
POR
= 3.6V
0.001
A
POR Rising Delay Time From FB to POR
105 150 210
ms
EN
EN rising 1.2
Enable Input Threshold V
IN
= 1.425V to 3.6V
EN falling 0.4
V
Enable Input Bias Current V
EN
= 0 or 3.6V -1 +1 µA
THERMAL SHUTDOWN
T
J
rising
+165
Thermal-Shutdown Threshold Output on or off
T
J
falling
+150
°C
OUTPUT TRANSIENT
Load Transient I
OUT
= 20mA to 2A to 20mA, t
RISE
= t
FALL
= 1µs 3 %
Line Transient δV
IN
= 0.5V, t
RISE
= t
FALL
= 5µs 3 %