Datasheet
MAX6695/MAX6696
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
...........................................................................-0.3V to +6V
DXP1, DXP2................................................-0.3V to (V
CC
+ 0.3V)
DXN ......................................................................-0.3V to +0.8V
SMBCLK, SMBDATA, ALERT ...................................-0.3V to +6V
RESET, STBY, ADD0, ADD1, OT1, OT2 ...................-0.3V to +6V
SMBDATA Current .................................................1mA to 50mA
DXN Current ......................................................................±1mA
Continuous Power Dissipation (T
A
= +70°C)
10-Pin μMAX (derate 6.9mW/°C above +70°C) ........555.6mW
16-Pin QSOP (derate 8.3mW/°C above +70°C) .......666.7mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature .....................................................+150°C
Storage Temperature Range ............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C
Soldering Temperature (reflow) .......................................+260°C
ELECTRICAL CHARACTERISTICS
(V
CC
= +3.0V to +3.6V, T
A
= 0°C to +125°C, unless otherwise noted. Typical values are at V
CC
= +3.3V and T
A
= +25°C)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Voltage V
CC
3.0 3.6 V
Standby Supply Current SMBus static, ADC in idle state 10 μA
Operating Current Interface inactive, ADC active 0.5 1 mA
Conversion rate = 0.125Hz 35 70
Conversion rate = 1Hz 250 500
Average Operating Current
Conversion rate = 4Hz 500 1000
μA
T
RJ
= +25°C to +100°C
(T
A
= +45°C to +85°C)
-1.5 +1.5
T
RJ
= 0°C to +125°C (T
A
= +25°C to +100°C) -3.0 +3.0
T
RJ
= -40°C to +125°C (T
A
= 0°C to +125°C) -5.0 +5.0
Remote Temperature Error
(Note 1)
T
RJ
= -40°C to +125°C (T
A
= -40°C) +3.0
°C
T
A
= +45°C to +85°C -2.0 +2.0
T
A
= +25°C to +100°C -3.0 +3.0
T
A
= 0°C to +125°C -4.5 +4.5
Local Temperature Error
T
A
= -40°C to +125°C +3.0
°C
T
A
= +45°C to +85°C -3.8
T
A
= +25°C to +100°C -4.0
T
A
= 0°C to +125°C -4.2
Local Temperature Error
(MAX6695Y/MAX6696Y)
T
A
= -40°C to +125°C -4.4
°C
Power-On Reset Threshold V
CC
, falling edge (Note 2) 1.3 1.45 1.6 V
POR Threshold Hysteresis 500 mV
Undervoltage Lockout Threshold UVLO Falling edge of V
CC
disables ADC 2.2 2.8 2.95 V
Undervoltage Lockout Hysteresis 90 mV
Channel 1 rate 4Hz, channel 2 / local rate
2Hz (conversion rate register 05h)
112.5 125 137.5
Conversion Time
Channel 1 rate 8Hz, channel 2 / local rate
4Hz (conversion rate register 06h)
56.25 62.5 68.75
ms
High level 80 100 120
Remote-Diode Source Current I
RJ
Low level 8 10 12
μA