Datasheet

MAX4691–MAX4694
Low-Voltage 8:1 Mux/Dual 4:1 Mux/Triple SPDT/
Quad SPDT in UCSP Package
______________________________________________________________________________________ 17
MEASUREMENTS ARE STANDARDIZED AGAINST SHORT AT SOCKET TERMINALS.
OFF-ISOLATION IS MEASURED BETWEEN COM AND “OFF” NO TERMINAL ON EACH SWITCH.
ON LOSS IS MEASURED BETWEEN COM AND “ON” NO TERMINAL ON EACH SWITCH.
CROSSTALK IS MEASURED FROM ONE CHANNEL (A, B, C) TO ALL OTHER CHANNELS.
SIGNAL DIRECTION THROUGH SWITCH IS REVERSED; WORST VALUES ARE RECORDED.
V- IS NOT PRESENT ON THE MAX4694.
V+
V
OUT
V
IN
V-
GND
V+
V
IN
V
OUT
MEAS.
NETWORK
ANALYZER
50 50
50
OFF-ISOLATION = 20log
ON-LOSS = 20log
CROSSTALK = 20log
50
REF.
B
V-
V
OUT
V
IN
V
OUT
V
IN
A
CHANNEL
SELECT
C
W_, X_, Y_, Z_
W, X, Y, Z
10nF
10nF
MAX4691–
MAX4694
V
EN
EN
Figure 6. Off-Isolation, On-Loss, and Crosstalk
V+
V-
GND
V+
B
V-
A
CHANNEL
SELECT
1MHz
CAPACITANCE
ANALYZER
C
W_, X_, Y_, Z_
W, X, Y, Z
EN
MAX4691–
MAX4694
V- IS NOT PRESENT ON THE MAX4694.
Figure 7. Capacitance
Test Circuits/Timing Diagrams (continued)