Datasheet

MAX16060/MAX16061/MAX16062
1% Accurate, Quad-/Hex-/Octal-Voltage
µP Supervisors
2
______________________________________________________________________________________________________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
CC
= 2.0V to 5.5V, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at V
CC
= 3.3V, T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
, OUT_, IN_, RESET to GND ..............................-0.3V to +6V
TOL, MARGIN, MR, SRT, WDI to GND ...........-0.3V to V
CC
+ 0.3
Input/Output Current (RESET, MARGIN,
SRT, MR, TOL, OUT_, WDI).........................................±20mA
Continuous Power Dissipation (T
A
= +70°C)
16-Pin TQFN (derate 16.9mW/°C above +70°C) ......1349mW
20-Pin TQFN (derate 16.9mW/°C above +70°C) ......1355mW
24-Pin TQFN (derate 16.9mW/°C above +70°C) ......1666mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature .....................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Operating Voltage Range V
CC
(Note 2) 1.0 5.5 V
V
CC
= 3.3V, OUT_, RESET not asserted 45 65
Supply Current (Note 3) I
CC
V
CC
= 5V, OUT_, RESET not asserted 50 70
µA
UVLO (Undervoltage Lockout) V
UVLO
V
CC
rising 1.62 1.80 1.98 V
UVLO Hysteresis V
UVLO_HYS
65 mV
IN_ (See Table 1)
3.3V threshold, TOL = GND 3.069 3.102 3.135
3.3V threshold, TOL = V
CC
2.904 2.937 2.970
2.5V threshold, TOL = GND 2.325 2.350 2.375
2.5V threshold, TOL = V
CC
2.200 2.225 2.250
1.8V threshold, TOL = GND 1.674 1.692 1.710
Threshold Voltages (IN_ Falling) V
TH
1.8V threshold, TOL = V
CC
1.584 1.602 1.620
V
TOL = GND 0.390 0.394 0.398
Adjustable Threshold
(IN_ Falling)
V
TH
TOL = V
CC
0.369 0.373 0.377
V
IN_ Hysteresis V
TH
_
HYS
IN_ rising 0.5 % V
TH
Fixed thresholds 3 16 µA
IN_ Input Current
Adjustable thresholds -100 +100 nA