Datasheet

30Maxim Integrated
MAX11129–MAX11132
3Msps, Low-Power, Serial 12-/10-Bit,
8-/16-Channel ADCs
Table 12. Custom Scan0 Register
Table 13. Custom Scan1 Register
Table 14. SampleSet Register
BIT NAME BIT
DEFAULT
STATE
FUNCTION
CUST_SCAN0 15:11 Set to 10100 to select the Custom Scan0 register.
CHSCAN15 10 0 Set to 1 to scan AIN15. Set to 0 to omit AIN15.
CHSCAN14 9 0 Set to 1 to scan AIN14. Set to 0 to omit AIN14.
CHSCAN13 8 0 Set to 1 to scan AIN13. Set to 0 to omit AIN13.
CHSCAN12 7 0 Set to 1 to scan AIN12. Set to 0 to omit AIN12.
CHSCAN11 6 0 Set to 1 to scan AIN11. Set to 0 to omit AIN11.
CHSCAN10 5 0 Set to 1 to scan AIN10. Set to 0 to omit AIN10.
CHSCAN9 4 0 Set to 1 to scan AIN9. Set to 0 to omit AIN9.
CHSCAN8 3 0 Set to 1 to scan AIN8. Set to 0 to omit AIN8.
2:0 000 Unused.
BIT NAME BIT
DEFAULT
STATE
FUNCTION
CUST_SCAN1 15:11 Set to 10101 to select the Custom Scan1 register.
CHSCAN7 10 0 Set to 1 to scan AIN7. Set to 0 to omit AIN7.
CHSCAN6 9 0 Set to 1 to scan AIN6. Set to 0 to omit AIN6.
CHSCAN5 8 0 Set to 1 to scan AIN5. Set to 0 to omit AIN5.
CHSCAN4 7 0 Set to 1 to scan AIN4. Set to 0 to omit AIN4.
CHSCAN3 6 0 Set to 1 to scan AIN3. Set to 0 to omit AIN3.
CHSCAN2 5 0 Set to 1 to scan AIN2. Set to 0 to omit AIN2.
CHSCAN1 4 0 Set to 1 to scan AIN1. Set to 0 to omit AIN1.
CHSCAN0 3 0 Set to 1 to scan AIN0. Set to 0 to omit AIN0.
2:0 000 Unused.
BIT NAME BIT DEFAULT STATE FUNCTION
SMPL_SET 15:11 Set to 10110 to select the SampleSet register.
SEQ_LENGTH 10:3 00000000
8-bit binary word indicating desired sequence length. The equation is:
Sequence length = SEQ_LENGTH + 1
00000000 = Sequence length = 1
11111111 = Sequence length = 256
Coding: Straight binary
Maximum length: 256 ADC conversions
2:0 Unused.