17.2 Transmit Signaling
Figure 17-2.Simplified Diagram of Transmit Signaling Path
TRANSMIT
SIGNALING
REGISTERS
SIGNALING
BUFFERS
PER-CHANNEL
CONTROL
TSER
TSIG
T1/E1 DATA
STREAM
PER-CHANNEL
CONTROL
SSIE1 - SSIE4
B7
T1TCR1.4
1
0
0
1
0
1
PCPR.3
ONLY APPLIES TO T1 MODE
17.2.1 Processor-Based Transmit Signaling
In processor-based mode, signaling data is loaded into the transmit-signaling registers (TS1–TS16) via
the host interface. On multiframe boundaries, the contents of these registers are loaded into a shift register
for placement in the appropriate bit position in the outgoing data stream. The user can utilize the transmit
multiframe interrupt in status register 4 (SR4.4) to know when to update the signaling bits. The user need
not update any transmit signaling register for which there is no change of state for that register.
Each transmit signaling register contains the robbed-bit signaling (T1) or TS16 CAS signaling (E1) for
two time slots that will be inserted into the outgoing stream if enabled to do so via T1TCR1.4 (T1 Mode)
or E1TCR1.6 (E1 Mode). In T1 mode, only TS1 through TS12 are used.
Signaling data can be sourced from the TS registers on a per-channel basis by utilizing the software-