Datasheet

DS1780
18 of 28
INTERRUPT INT STATUS REGISTER 2 (ADDRESS 0X42; POWER-UP
DEFAULT=00h) Table 10.4
BIT NAME R/W DESCRIPTION
0 +12V_Error R A 1 indicates a High or Low limit has been exceeded.
1
-12V/
V
CCP2
_Error
R A 1 indicates a High or Low limit has been exceeded.
2 Reserved R 0
3 Reserved R 0
4
Chassis_Error
R A 1 indicates Chassis Intrusion has gone high.
5 Reserved R 0
6 Reserved R 0
7 Reserved R 0
Note: Anytime the INT Status Registers are read out, the conditions (i.e., Registers) that are read are
automatically reset to power-up state (except CHS, which can only be cleared by CHS reset). In the case
of the VOLTAGE priority indication, if two or more voltages were out of LIMITS, then another
indication would automatically be generated if it were not handled during the ISR.
The errant voltage may be masked until the operator has time to clear the errant condition or set the limit
higher/lower.
INT MASK REGISTER 1 (ADDRESS 0X43; POWER-UP DEFAULT=00h)
Table 10.5
BIT NAME R/W DESCRIPTION
0 +2.5V R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
1 +V
CCP1
R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
2 +3.3V R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
3 +5V R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
4 Temp R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
5 Reserved R/W Power on default = 0.
6 FAN1 R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
7 FAN2 R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
INT MASK REGISTER 2 (ADDRESS 0X44; POWER-UP DEFAULT=00h)
Table 10.6
BIT NAME R/W DESCRIPTION
0 +12V R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
1 -12V/V
CCP2
R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
2 Reserved R/W Power-up Default = 0.
3 Reserved R/W Power-up Default = 0.
4
CHS_sec
(Chassis
Intrusion)
R/W
A 1 disables the corresponding interrupt status bit for
INT interrupt.
5 Reserved R/W Power-up Default = 0.
6 Reserved R/W Power-up Default = 0.
7 Reset Enable R/W A 1 enables the RESET in the configuration register.