SDS
6
CONTINUED: SECTION 8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
Lithium Carbonate
Not applicable
Not available
Not applicable
Not applicable
Not applicable
1-Methyl-2-Pyrrolidinone
Not applicable
Not available
Not applicable
Not applicable
TWA = 40 mg/m³
TWA= 10 ppm
STEL = 80 mg/m³
STEL = 20 ppm
8.2 Exposure controls
8.2.1 Appropriate engineering controls :
Substance/mixture related measures to prevent exposure during identified uses:
- Avoid charging batteries in areas where hydrogen gas accumulate.
- Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive collect and transport flammable
gases in ventilation systems.
- Insure proper ventilation is present and electrolyte mist and vapours.
Structural measures to prevent exposure:
- Avoid charging batteries in areas where hydrogen gas accumulate.
-Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive collect and transport flammable
gases in ventilation systems.
-Insure proper ventilation is present and electrolyte mist and vapours.
Organizational measures to prevent exposure: Not available
Technical measures to prevent exposure:
-Insure proper ventilation is present and electrolyte mist and vapours.
8.2.2 Individual protection measures, such as personal protective equipment:
Eye and face protection
- Wear ANSI approved safety glasses with side shield during normal use.
- Wear NIOSH approved face shield with safety glasses and H.V protection during intentional disassembly.
Skin protection
Hand protection
- Wear nitrile butyl rubber, neoprene, or PVC glove during battery component disassembly.
- Discard contaminated work clothing after one work day.
Other skin protection
- Wear protective clothing during battery component disassembly.
- Discard contaminated work clothing after one work day.
Respiratory protection :
- None required during normal use.
- Wear NIOSH or European Standard EN 149 approved full or half face piece (with goggles) respiratory protective equipment when
necessary.
- In lack of oxygen(< 19.5%), wear the supplied-air respirator or self-contained oxygen breathing apparatus.
- In case exposed to particulate material, the respiratory protective equipments as follow are recommended; facepiece filtering
respirator or air-purifying respirator, high-efficiency particulate air(HEPA) filter media or respirator equipped with powered fan,
filter media of use (dust, mist, fume)
8.2.3 Environmental exposure controls
Substance/mixture related measures to prevent exposure: Not available
Instruction measures to prevent exposure: Not available
Organizational measures to prevent exposure: Not available
Technical measures to prevent exposure: Not available