SDS

2
SECTION 4. FIRST AID MEASURE
The product contains organic electrolyte. In case of electrolyte leakage from the battery, actions described below are required.
Eye contact:
Flush the eyes with plenty of clean water for at least 15 minutes immediately, without rubbing, and call
a doctor. If appropriate procedures are not taken, this may cause an eye irritation.
Skin contact:
Wash the contact areas off immediately with plenty of water and soap. If appropriate procedures are
not taken, this may cause sores on the skin.
Inhalation:
Remove to fresh air immediately, and call a doctor.
SECTION 5. FIRE FIGHTING MEASURES
• Use specified extinguishers (gas, foam, powder) and extinguishing system under the Fire Defense Law.
• Since corrosive gas may be produced at the time of fire extinguishing, use an air inhalator when danger is predicted.
• Use a large amount of water as a supportive measure in order to get cooling effect if needed. (Indoor/outdoor fire hydrant)
• Carry away flammable materials immediately in case of fire.
• Move batteries to a safer place immediately in case of fire.
SECTION 6. ACCIDENTAL RELEASE MEASURES
• Wipe off with dry cloth
• Keep away from fire
• Wear safety goggles, safety gloves as needed
SECTION 7. HANDLING AND STORAGE
Storage:
Store within the recommended limit of -30
o
C to 45
o
C (-22
o
F to 113
o
F), well-ventilated area. Do not
expose to high temperature (60
o
C/140
o
F). Since short circuit can cause bum hazard or safety vent to
open, do not store with metal jewelry, metal covered tables, or metal belt.
Handling:
Do not disassemble, remodel, or solder. Do not short+ and- terminals with a metal. Do not open the
battery pack.
Charging:
Charge within the limits of 0
o
C to 40
o
C (32
o
F to 104
o
F) temperature. Charge with specified charger
designed for this battery pack.
Discharging:
Discharge within the limits of -20
o
C to 60
o
C (-4
o
F to140
o
F) temperature.
Disposal:
Dispose in accordance with applicable federal, state and local regulations.
Caution:
FOR SAFE OPERATION, SEE INSTRUCTION MANUAL.USE ONLY WITH MAKITA HIGH
CAPACITY CHARGER. CHARGING ROOM TEMP.:10
o
C~ 40
o
C. DO NOT EXPOSE BATTERY
TO WATER OR RAIN.DO NOT DESTROY BATTERY BY FIRE.
SECTION 8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
Acceptable concentration:
Not specified in ACGIH.
Facilities:
Provide appropriate ventilation such as local ventilation system in the storage.
Protective clothing:
Gas mask for organic gases, safety goggle, safety glove.