DVM Series Direct Vent Gas Fireplace Models: 500DVM, 600DVM Installation & Operating Instructions WARNINGS If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.
CONTENTS DVM Series Direct Vent Gas Fireplace Thank you and congratulations on your purchase of a Majestic Fireplace. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important Safety Information......................................3 Code Approval.......................................
IMPORTANT SAFETY INFORMATION DVM Series Direct Vent Gas Fireplace INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous.
IMPORTANT SAFETY INFORMATION DVM Series Direct Vent Gas Fireplace ! IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplace to give off some odor the first time it is burned. This is due to the manufacturing process.
product features and code approval product SPECIFICATIONS • This appliance has been certified for use with either • • • • • • natural or propane gas. See appropriate data plates. This appliance is not for use with solid fuels. The appliance is approved for bedroom or bedsitting room installations. The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.
FIREPLACE & FRAMING DIMENSIONS DVM Series Direct Vent Gas Fireplace D Min. Rough Opening Depth V W K T N M L V 1/2” or 5/8” S - Min. Rough Opening Width U Min. Rough Opening Height 5” R 5/8” 1/2” 2” B G H I 1/2” 5/8” Figure 2 Fireplace & Framing Dimensions O 256O” (64 mm) Ref. A B C D E F G H I J K L M N O P Q R S T U V W C J 500DVM 41" (1041 mm) 46B\zn" (1176 mm) 752525 DVM MDV dims 40C\," (1026 mm) 32C\zn" (818 mm) 36" (914 mm) 32ZB\zn" (837 mm) 42M\zn" (1079 mm) 34Z\x" (876 mm) 23C
pRE-INSTALLATION INFORMATION DVM Series Direct Vent Gas Fireplace Before You Start fireplace framing Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
pRE-INSTALLATION INFORMATION DVM Series Direct Vent Gas Fireplace Fireplace Location Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
clearances DVM Series Direct Vent Gas Fireplace WARNING Clearances to combustibles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
DVM Series Direct Vent Gas Fireplace SECURE FIREPLACE to floor or framing The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6 . Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets or nailing flanges are designed to accommodate two thickness of wall boards (1/2" or 5/8").
OPTIONAL TOP vent APPLICATION The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration the appliance can be converted by following the steps below. When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.
NOTICE WARNING DVM Series Direct Vent Gas Fireplace VENTING INSTALLATION Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. Failure to follow these instructions will void the warranty.
VENTING INSTALLATION WARNING Horizontal sections of this vent system require a minimum of 3” clearances to combustibles at the top of the flue and 1” clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1” clearance all around the flue is acceptable at this point of penetration. If vertical rise is 7Z\x” feet or higher when top venting, the clearance to combustibles is 1” on all sides of the horizontal run.
Venting installation installation planning There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness. for horizontal termination Select the amount of vertical rise desired. All horizontal run of venting must have 1/4" rise for every 12" of run towards the termination below 7Z\x feet of vertical rise. With 7Z\x feet or
venting installation DVM Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A D L V E C B V F Figure 11 Horizontal Vent Termination Locations B Fixed Closed Ope ra V B B V B V VENT TERMINATION B V J A CFM145a V Fixed Closed Operable ble X AIR SUPPLY INLET X M I V K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 US Installations2 CFM145a A = Clearance above grade, veranda, porch, 12” (30 cm)DV Ter
venting installation DVM Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Alcove Applications* Inside Corner Outside Corner G= Combustible 6" (152 mm) G Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall Figure 12 Allowable Venting F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min.
Venting installation DVM Series Direct Vent Gas Fireplace Rear Wall Vent installation (5"x8" Venting only) When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance. Only an MHSC brand termination is allowed for this application. • The maximum horizontal distance between the rear • of the appliance and the termination is 20" (508 m). Figure 14. Only one 45° elbow is allowed in these installations. 2.
venting installation DVM Series Direct Vent Gas Fireplace Vent Cap T HO 6. Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap. Figure 19 7. Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1Z\v". Apply silicone to the outer pipe connection. Fasten all vent connections with screws provided. 8.
WARNING venting installation DVM Series Direct Vent Gas Fireplace When installing the appliance as a rear vent unit, the 90°, 45° transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations, and unless specifically mentioned should be ignored when calculating venting layouts. • The maximum number of 90° elbows per side wall installation is three (3).
venting installation DVM Series Direct Vent Gas Fireplace • The maximum number of 45° elbows permitted per side • • wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18" (457 mm). This does not apply if the 45° elbows are installed on the vertical part of the vent system. The maximum number of elbow degrees in a system is 270°. Figure 24 10Z\x" (267
venting installation DVM Series Direct Vent Gas Fireplace 9Z\x" (241 mm) Screws Firestop Minimum 4" Clearance 9Z\x" (241 mm) Ground Combustible Wall 24” Minimum Framing Window Well Gravel Drain 7Z\x" (190 mm) Foundation Wall FP1965 VO584-100 NOTE: #1222DA reducer must be used when 4x6B\," venting is preferred. #7TDVP58 reducer must be used when 4"x7" ventingVO584-100 is preferred. Reducer must be installed directly onto unitOpening at fireplace collar before Vent vertical rise.
venting installation DVM Series Direct Vent Gas Fireplace WARNING vertical through-the-roof applications A restrictor disc must be installed on any vertical termination that is higher than 12'. Install restrictor disc as shown in Figure 29 for vertically vented applications. 40' Maximum Height 8' Minimum Height 10' Maximum Up to three (3) restrictor discs may be needed for 40' installation. Support Straps Every 3' The two (2) restrictor discs suppled will work for most installations.
venting installation 1 2 3 4 DVM Series Direct Vent Gas Fireplace Example: Elbow 1 Elbow 2 Elbow 3 Elbow 4 Total Angular Variation = = = = = 90° 45° 45° 90° 270° Roof Flashing Wall Strap 45° Elbows 1 2 3 4 FP1669 Figure 31 Maximum Elbow Usage Flat ceiling installation FP1969 FP1179 installation for vertical termination FP1179 1. Determine themax routebends your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset.
venting installation DVM Series Direct Vent Gas Fireplace Nails NOTE: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure to meet the minimum allowable clearances to combustibles. Do not fill any of the required clearance spaces with insulation.
NOTE FLEX VENTING INSTALLATION F l e x v e n t p i p e s p a c e r s : R e f e r t o manufacturer’s specifications for correct positioning of the spacer springs to maintain proper distance between inside and outside pipe. 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Flex kits may not be modified.
FLEX VENTING INSTALLATION DVM Series Direct Vent Gas Fireplace Flashing Rigid Pipe Length Termination Cap Storm Collar Roof Support Rigid Pipe Length Screws (3 Places equidistant just above gear clamp) Flex to Pipe Adapter Gear Clamp 1C\v" Flexible Pipe and Adapter Outer Collar Overlap Flex to Pipe Adapter Gear Clamp Firestop UL1777 Flex Vent Figure 39 FP1975 Typical Pipe Connection pipe connection UL1777 Flex PIpe Screws (3 Places equidistant just above gear clamp) DVFF8A/8 5" x 8" to 5" x 8"
FLEX VENTING INSTALLATION DVM Series Direct Vent Gas Fireplace 4" x 7" Flex Pipe If you prefer to use 4" x 7" flex pipe, you must install model 7TDVP58 reducer (5" x 8" to 4" x 7") onto the fireplace collar. Then follow the the assembly guidelines for 5" x 8" flex venting. UL1777 Flex Vent 1C\v" Flexible Pipe and Adapter Outer 5" x 8" to 4" x 7" Adapter (7TDVP58) Gear Clamp Screws (3 places, equidistant just above gear clamp) Appliance Starting Collar Figure 41 Typical 4" x 7" Appliance Connection
fireplace installation DVM Series Direct Vent Gas Fireplace check gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type. A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
DVM Series Direct Vent Gas Fireplace Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION WARNING fireplace installation A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 46 NOTE : The gas line connection may be made using 1/2" rigid tubing or an approved flex connector.
CHECK GAS PRESSURE and ELECTRICAL INSTALLATION - MILLIVOLT DVM Series Direct Vent Gas Fireplace WARNING 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 18" (457 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
Electrical installation - MILLIVOLT DVM Series Direct Vent Gas Fireplace Remote Wall mounted Switch (for millivolt valves only) WARNING A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 48. Do not extend beyond the wall switch wire length provided. NOTE: Extended lengths of wire may cause the fireplace not to function properly.
DVM Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - Millivolt WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
OPERATING INSTRUCTIONS - Millivolt DVM Series Direct Vent Gas Fireplace Lighting pilot for the first time - millivolt WARNING approved leak testing method You may check for gas leaks with the following methods only: • Soap and water solution If using a soap and water solution to test for leaks, DO NOT spray solution onto control body. • An approved leak testing spray DANGER • Electronic sniffer NOTE: Remove any excessive pipe compound from the connections.
OPERATING INSTRUCTIONS - MILLIVOLT DVM Series Direct Vent Gas Fireplace Lighting burner - millivolt main burner switch ON RS F OF The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. Lighting the burner On/Off/RS Switch Depress and turn the knob counterclockwise to the “ON” position.
SIGNATURE COMMAND - CHECK GAS PRESSURE and ELECTRICAL INSTALLATION DVM Series Direct Vent Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
ELECTRICAL INSTALLATION DVM Series Direct Vent Gas Fireplace JUNCTION BOX WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall. Junction box was installed at the factory. 120V AC 3. The junction box cover has a factory installed “romex” style 60Hz strain relief connector.
ELECTRICAL INSTALLATION DVM Series Direct Vent Gas Fireplace Optional AC Module To Junction Box in Fireplace Pilot { Plug in Connector Optional Blower Optional Light { White Black White Black Optional { White Black Aux. Green Connector Pin To Control Board Input 300 Watt Max.
OPTIONAL FAN BLOWER SYSTEMS The black and white wires on the AC box wiring harness are marked ‘Blower’, ‘Light’ and ‘Aux’. It is important to use the wires marked ‘Blower’ or the control will not work correctly. WARNING WARNING Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
OPTIONAL FAN BLOWER SYSTEMS DVM Series Direct Vent Gas Fireplace BLOTSDV AUTOMATIC THERMOSTAT BLOWER 120VAC Receptacle Junction Box BLACK GREEN WHITE BLACK WHITE BLACK BLACK Speed Control Figure 53 BLOTSDV Blower Wiring Diagram Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance FP2685 with prevailing codes.
DVM Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND WARNING for your safety read before lighting If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions for match lighting. B. BEFORE OPERATING smell all around the appliance area for gas.
OPERATING INSTRUCTIONS - SIGNATURE COMMAND DVM Series Direct Vent Gas Fireplace OPERATing INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on page 38. If you do not smell gas, go to next step. 4.
DVM Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS FEATURES RF Receiver ON/OFF Command Center • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Med/Low Operation • Optional Wall Mounting Control Board • • • • • • • • • • Electronic Ignition Pilot Lockout safety feature Electric Power Regeneration from Thermopile to save battery 6-hour Automatic Shut Down Option Convenient NG/LP Gas
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS DVM Series Direct Vent Gas Fireplace SYSTEM CONFIGURATION/SETUP All System configuration/setup is done on the Command Center. NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. Intermittent/Standing Pilot Setup (Default intermittent) 1. Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot. 2.
DVM Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS FUNCTIONS/OPERATION Turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below). For memory feature. Pilot Safety Lockout Function 1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens.
EYEBROW, glass frame & Brick DVM Series Direct Vent Gas Fireplace EYEBROW INSTALLATION Remove top louver assembly before installing eyebrow. 1. Unhook top louver assembly. Set aside. Figure 55 2. Attach canopy to underside of top outer shell with three (3) screws provided. Figure 56 3. Hook top louver assembly back into place. Louver Assembly Glass Frame Clamps Figure 55 Remove Top Louver Assembly FP2417 FP2417 louvers CAUTION Figure 57 Remove Glass Frame Each clamp has a quick spring force.
Logs and rock wool installation DVM Series Direct Vent Gas Fireplace CAUTION 1. Distribute one layer of rock wool to cover all round burner ports. Do not cover rectangular slots, located in front and rear. Figure 58 NOTE: Placing rock wool on burner provides glowing embers. For best results, pull the rock wool apart into pieces the size of a dime or smaller. Do not use the entire bag of rock wool to cover the burner. This could cause the flame to burn poorly and may lead to sooting.
Logs and rock wool installation DVM Series Direct Vent Gas Fireplace 4. Place the right middle log by aligning the holes in the bottom of the log with the two pins located on the right side of the burner. Figure 61 Right Middle Log LG668 Figure 61 Place Right Middle Log 5. Place the front left log by setting the notch LG668on the bottom of the log on the very far left tong of the grate, and resting the right DVM right log the second left tong of end ofmiddle the log onto the grate. Figure 62 6.
WARNING DVM Series Direct Vent Gas Fireplace Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season cleaning and maintenance Thermocouple Thermopile Millivolt Pilot Burner, Pilot and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
cleaning and maintenance DVM Series Direct Vent Gas Fireplace Vent System The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. Glass Door Thoroughly clean the inside of the glass door after using the fireplace for ten hours.
TROUBLESHOOTING DVM Series Direct Vent Gas Fireplace Standing Pilot Ignition SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will A. Wire disconnected. not light pilot after repeated triggering of B. Defective ignitor. piezo. C. No gas or low gas pressure. D. No Propane/LPG in tank 2. Pilot will not stay lit A. Defective thermocouple after carefully following lighting instructions. B. Defective valve 3. Pilot burning, valve A.
TROUBLESHOOTING DVM Series Direct Vent Gas Fireplace Standing Pilot Ignition SYMPTOM POSSIBLE CAUSE ACTION 4. Frequent pilot outage problem. A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame or too low, causing pilot impingement on thermocouple. safety to drop out 5. The pilot and main burner extinguish while in operation A. Inner vent pipe leaking exhaust gases back into system A. Check for flue product leak. Replace defective pipe section. B.
TROUBLESHOOTING DVM Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION Install batteries and/or plug in the AC board FAULT No beep in about 8 seconds A Using battery? Make sure Command Center and the control board are connected by a 2 feet or 15 feet cable After the beep Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center No beep or no sound from the valve indicating pilot solenoid open B No sparking on the pilot C Sparking doesn
REPLACEMENT PARTS DVM Series Direct Vent Gas Fireplace firebox components 6 5 7 2 3 4 1 8 8 10 9 Ref. Description Qty. 1. Junction Box Assy. 1 2. Top Louver Assy. 1 3. Bottom Louver Door Assy. 1 4. Glass Frame Assy 1 5. Eyebrow 1 6. Insulation Board 1 Accessories / Field Installed Options 7. Firebrick - Tavern Brown 1 7. Firebrick - Cottage Red 1 8. Blower 1 9. Thermostat Sensor 1 10. Speed Control 1 8, 9 ,10 T-stat Blower w/ Speed Control 1 8.
REPLACEMENT PARTS DVM Series Direct Vent Gas Fireplace Standing Pilot - Millivolt Control 2I 1 2C 2T 2 5 4 6 3 8 9 7 10 11,12,13,14,15,16 752525 DVM millivolt parts 54 75D2525
REPLACEMENT PARTS Standing Pilot - Millivolt Parts DVM Series Direct Vent Gas Fireplace Ref. Description Qty. 500DVMNV 500DVMPV 600DVMNV 1. Gas Valve Assy. 1 37D0117 37D0118 37D0117 2. Pilot Assy. 1 37D0018 37D0019 37D0018 2C. Replacement Thermocouple 1 37D1067 37D1067 37D1067 2I. Replacement Igniter w/Wire 1 37D1069 37D1069 37D1069 2T. Replacement Thermopile 1 37D1068 37D1068 37D1068 3. Burner Tube 1 56D2175 56D2175 56D2175 4. Flex Hose w/ Shutoff Valve 1 69D0030 69D0030 69D0030 5.
REPLACEMENT PARTS DVM Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM 1 2 4 3 5 6 8 7 12 13, 14, 15, 16, 17 9 19 752523 MDV DVM SC parts 56 75D2525
REPLACEMENT PARTS DVM Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM Ref. Description Qty. 500DVMNSC 500DVMPSC 600DVMNSC 600DVMPSC 1. Gas Valve Assy. 1 80D0001 80D0002 80D0001 80D0002 2. Pilot Assy. 1 80D0006 80D0007 80D0006 80D0007 3. Control Box 1 80D0018 80D0019 80D0018 80D0019 4. Command Center 1 80D0005 80D0005 80D0005 80D0005 5. Burner Tube 1 56D3099 56D3099 56D3099 56D3099 6. Flex Hose w/ Shutoff Valve 1 69D0030 69D0030 69D0030 69D0030 7. Injector 1 57D1030 20H3144 56D0614 57D0680 8.
DVM Series Direct Vent Gas Fireplace Logs Ref. Description Qty. 1. Rear Log #1 1 2. Left Middle Log #2 1 3. Right Middle Log #3 1 4. Left Front Log #4 1 5. Right Front Log #5 1 6. Upper Left Log #6 1 7. Upper Middle Log #7 1 8.
REPLACEMENT PARTS 2 DVM Series Direct Vent Gas Fireplace 3 2 1 5 4 Accessories / Field Installed Options Ref. Description Qty. 1. Metal Trim - Brass 752525 1 1. Metal Trim - Pewter 1 DVM accessories 1. Metal Trim - Black 1 2. Brass Louvers 8 2. Pewter Louvers 8 3. Screen Frame - Black 1 4. Cabinet Door Frame - Black 1 4. Cabinet Door Frame - Iron Age 1 4. Cabinet Door w/Screen - Black 1 4. Cabinet Door w/Screen - Iron Age 1 5. Arched Front w/Lower Control Door - Black 1 5.
VENTING COMPONENTS DVM Series Direct Vent Gas Fireplace 1 7 4 8 9 HO T 5 2 3 6 10 11 VENT COMPONENTS FOR 4" X 6B\," (Simpson Duravent, Selkirk) 4" x 6Z\x" (Metal-Fab) Current Old Simpson Simpson Duravent Duravent Qty./ or MHSC or MHSC Selkirk Metal-Fab Item Box Description Part no. Part no. Part no. Part no.
VENTING COMPONENTS DVM Series Direct Vent Gas Fireplace VENT COMPONENTS FOR 5" X 8" Current Old Simpson Simpson Duravent Duravent Qty./ or MHSC or MHSC Selkirk Metal-Fab Item Box Description Part no. Part no. Part no. Part no.
DVM Series Direct Vent Gas Fireplace VENTING COMPONENTS HORIZONTAL VENTING - 4" x 7" Horizontal Vent Termination Kits Description Model Number Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10" to 16" 7TDVSCTK Adjustable Termination Pipe, 90° Elbow, Firestop, and Cool Touch Termination w/ Siding Shield Rear Vent Cool Touch Termination w
VENTING COMPONENTS DVM Series Direct Vent Gas Fireplace VERTICAL VENTING - 4" x 7" Description Model Number Vertical Vent Termination Kits Vertical Vent Termination w/ Storm Collar (flashing NOT included) 7TDVSKV Vertical Vent Termination w/ Storm Collar - 8 pack (flashing NOT included) 7TDVSKV/8 Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm Collar and Ceiling Support Kit 7TDVSKVA* Vertical Vent Termination w/ 6/12 - 12/12 Flashing, Storm Collar and Ceiling
DVM Series Direct Vent Gas Fireplace 64 75D2525
DVM Series Direct Vent Gas Fireplace 75D2525 65
Massachusetts Residents Only — Please read and follow these special requirements DVM Series Direct Vent Gas Fireplace NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence.
DVM Series Direct Vent Gas Fireplace Limited lifetime warranty policy Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
Based on CSA P.4.1-09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 500DVMNV 71.7 500DVMPV 77.9 500DVMNSC 76.4 Recherchez dans la brochure 500DVMPSC les caractéristique de82.1 rendement 600DVMNV 67.6au gaz énergétique de foyer 600DVMPV Énerguide74.3 600DVMNSC 71.0 Based CSA P.4.1-09 Selonon CSA P.4.1-09 600DVMPSC 77.7 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.