4.5 Configuration Settings
There are a number of configurable operating parameters, and the factory-default settings should work for most
applications. However, some applications might require slight configuration changes.
This section describes how to configure the following settings:
Config-1 mode, LEDs 1-2: Sync-mode settings
Config-1 mode, LEDs 4-6: 4
th
pair settings
Config-1 mode, LED 7: Vsync polarity settings
Config-1 mode, LED 8: Hsync polarity settings
Config-2 mode, LED 1-2: Clamp-mode settings
Config-2 mode, LED 3: 4
th
pair termination settings
Nearly all settings are available from the front-panel buttons/LEDs. The enclosure does not need to be opened
unless an option module is being installed or removed, or settings specific to the option module need to be
changed.
4.5.1 Configuration Modes 1 & 2
For configuration settings, the receiver must be in Config-1 or Config-2 mode (CFG indicator is on or flashing).
Once in a configuration mode, any changes are effective immediately and are saved in non-volatile memory.
To enter configuration-mode-1:
Press and hold the CFG button until the CFG indicator turns on.
o Once in this mode, the LED indicators 1-8 will display the current settings for the Config-1
settings.
To enter configuration-mode-2:
Press and hold the CFG button until the CFG indicator turns on.
Press the SEL button exactly 5 times. The CFG indicator will start flashing.
o Once in this mode, the LED indicators 1-8 will display the current settings for the Config-2
settings.
To exit configuration-mode:
Leave the buttons untouched for 10 seconds. The CFG indicator will turn off (normal-mode).
Or, press the CFG button once. You will immediately leave Config-1 or Config-2 mode.
To quickly reset all user-configurable options back to factory-default settings:
1. Disconnect the DC power cable (or AC power).
2. Press and hold the CFG button.
3. Connect the DC power cable (or AC power). All LEDs blink 3 times, indicating all settings are now changed
back to factory-defaults.