Instructions / Assembly

www.LockState.com
LockState LS-6600 User Manual
Before installing and using your LS-6600, please review the following important
notes:
The original master access code is set to 111111(Factory Default)
ALL user and master access codes must be 6 digits in length
The LS-6600 can save up to 199 sets of user access codes and 1 master access code (Total
200)
The master access code can be used to enroll or delete users. It is also used for one-button
passage mode (in this mode the lock opens with any single button pressed).
When the batteries are low you will hear 6 consecutive beeps each time the lock is operated.
Operating the Lock
Electronic Access: The lock opens with either the master access code or a user codes. To open
the lock, enter your 6 digit access code. The green light flashes and the lock plays a sequence of
beeps indicating it has been unlocked. Within 5 seconds, turn the handle to open the door.
Key Access/Passage Mode: Remove the cap in the center of the handle with tool 1 provided.
Insert the key and turn counter-clockwise 3 to 5 full rotations until the outside door handle
engages the latch. Remove the key and the lock remains in passage mode (unlocked). To exit
passage mode and re-lock, turn the key clockwise 3 to 5 full rotations until the outside handle no
longer engages the latch.
Programming the Lock
1. Enrolling Users
Each user that you enroll has 2 numbers associated with them: (1) a 3 digit user number and (2) a
6 digit access code. The 3 digit user number is used to delete the user from the system. We
recommend keeping a chart of all user numbers and their associated access codes. For all
programming, after completing a step successfully you will hear only a 3 beep confirmation. If
completing steps unsuccessfully, you will hear the 3 beep confirmation followed by a 6 beep
failure sound. In this case please wait 5 seconds and start the entire process over. After
completing a final step successfully, you will hear a different 5 beep confirmation sound.
1. Steps for Enrolling Users
1) Press “# # ”
2) Enter your master access code (factory default “111111”)
3) Press # * *
4) Enter a 3 digit user number (Careful – entering an existing # will override the old #)
5) Enter a 6 digit user access code
6) Re-enter the 6 digit user access code
(EXAMPLE: “## ” + “111111” +“#** ”+“ 001”+“ 123456”+“123456”)
2. Steps for Changing Codes (Master Codes AND User Codes)
(1)press “# # ”, (2) enter the code being changed, (3)enter * * * (4)enter new code, (5)re-enter