User's Manual
BSM-700 Specification Page 29/31 2014/03/31
LTC Network Access Confidential
11 Criteria for Reliability Test
No.
Item
Condition
Unit
1
High Temperature High Humidity
Storage Test
1. Temperature/Humidity: 75
℃
±2
℃
95%±3RH
2. Test Time: 24Hrs
10pcs
2
Low Temperature Storage Test
1. Temperature:
-
40
℃
±2
℃
2. Test Time: 24Hrs
10pcs
3
3.1 Thermal Shock Test
1. High Temperature: 85
℃
15mins
2. Low Temperature: -40℃ 15mins
3. Temperature Rate: 25℃/Min
4. Duration: 200cycles
4pcs
3.1
-
1 X
-
Section Analysis
1. Environment: 21
℃
50%RH
2. Test location: ANT1, U2, XTAL1, U5
2pcs
4
Temperature Profile Test
1. Temperature: 70
℃
& 25
℃
2. Test Time: 6Hrs/Temp
3. Ping IP test
4. Test location: U2, U5, XTAL1,
2pcs
5
Operationa
l With Temperature Cycle Test
1. High Temperature/Humidity: 70
℃
90%RH 1H
2. Low Temperature: 0℃ 1H
3. Raise Time: 2℃/min Descend Time: 1℃/min
4. Duration: 10Cycles
2pcs
6
Power Cycling Test
1. Test Temperature/Humidity: 70
℃
90%RH 24Hrs &
25℃ 50%RH 24Hrs
2. Fixture: Power on 29mins & Power off 1min
3. Duration: 0.5H/Cycle ,Total 48Cycles
2pcs
7
Vibration Test
1. Vibration Wave: sine
2. Vibration Frequency: 10-300-10HZ 1G
3. Vibration Axis: Z Axis
4. Test time: 1Hr
2pcs