User Manual

18
Appliance dimensions
Setting up
Avoid positioning the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
The floor on which the appliance stands should be horizontal
and level.Compensate for uneven floors with the adjustable feet.
Do not cover ventilation openings
or grille.
Standard EN 378 specifies that the room in
which you install your appliance must have a
volume of 1 m
3
per 8 g of R 600a refrigerant
used in the appliance, so as to avoid the forma-
tion of inflammable gas/air mixtures in the room
where the appliance is located in the event of
a leak in the refrigerant circuit. The quantity of
refrigerant used in your appliance is indicated
on the type plate on the inside of the appliance.
Always install the appliance directly against
the wall.
Place the appliance in its final position
at the place of installation.
Extend the adjustable foot at the bottom
hinge bracket until it rests on the floor
and then make a further 90° turn.
Saving energy
- Always ensure good ventilation. Do not cover ventilation open-
ings or grille.
- Always keep fan slits clear.
- Avoid positioning the appliance in direct sunlight or near cookers,
radiators or similar sources of heat.
- The energy consumption depends on the installation conditions,
e.g. the ambient temperature.
- Keep the time the appliance is open to a minimum.
Accumulated dust increases the energy consumption:
- Once a year, dust the refrigerating unit together with the metal
grid of the heat exchanger at the back of the appliance.
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating Room temperature
SN +10°C to +32°C
N +16°C to +32°C
ST +16°C to +38°C
T +16°C to +43°C
SN-ST +10°C to +38°C
SN-T +10°C to +43°C
Do not operate the appliance outside the
specied room temperature range.
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type
plate. The position of the type plate is shown in the section entitled
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating/three-phase
current) or energy-saving plugs. Risk of dam-
age to the electronic control system!