Concealed Duct Submittal
Sirocco
Brushless Digitally Controlled/Direct
Job Name/Locaon:
Date:
PO No.:
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)
For: File Resubmit
Approval Other
Tag #:
For a complete list of available accessories, contact your LG representave.
For connual product development, LG reserves the right to change specicaons without noce.
© LG Electronics U.S.A., Inc., Englewood Clis, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
1. Acceptable operating voltage: 187V-253V.
2. Wireless handheld remote controller requires an LG wired thermostat.
3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Adjust fan speed to correct for static pressure increases when using field-supplied air filter.
5. See Engineering Manual for sensible and latent capacities.
6. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied
and must be a minimum of four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must
be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national
codes.
7. Power wiring cable size must comply with the applicable local and national code.
8. The indoor unit comes with a dry helium charge.
9. Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and
the level difference is 0 ft. All capacities are net with a combination ratio between 95 - 105%.
10. Must follow installation instructions in the applicable LG installation manual.
11. Controller not included.
Notes:
Controls Features:
• Inverter (Variable Speed Fan)
• Internal Condensate Pump
• ESP Control
• Hot Start
• Auto Restart
• Child Lock
• Group Control
• Sleep Mode
• Timer On / O
• Controller Sold Separately
Oponal Accessories:
Cooling (°F WB)
Heating (°F DB)
57 ~ 77
59 ~ 81
Entering Mixed Air:
Page 1 of 2
Performance:
Nominal Cooling Capacity (Btu/h)
Nominal Heang Capacity (Btu/h)
Cooling Nominal Test Condions:
Indoor: 80°F DB / 67°F WB
Outdoor: 95°F DB / 75°F WB
Heang Nominal Test Condions:
Indoor: 70°F DB / 60°F WB
Outdoor: 47°F DB / 43°F WB
Electrical:
Power Supply (V¹/Hz/Ø)
Rated Amps (A)
208-230/60/1
Piping:
Installed Liquid Pipe (in., O.D.)
Installed Vapor Pipe (in., O.D.)
Liquid Connecon (in., O.D.)
Vapor Connecon (in., O.D.)
Drain (in., O.D. / I.D.)
Temperature Sensor
1-1/4, 1
Thermistor
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure (H/M/L) dB(A)
3
Filter Type
Net Weight (lbs.)
Shipping Weight (lbs.)
R410A
EEV
Washable
Fan:
Type
Quantity
Motor/Drive
Air Flow H/M/L (CFM)
Default External Static Pressure
4
(in wg)
Maximum External Static Pressure
Simple Remote Controller - PREMTC00U
MultiSITE™ CRC1 Controller - PREMTBVC0
MultiSITE™ CRC1+ Controller - PREMTBVC1
Premium Remote Controller - PREMTA000
Wireless Handheld Remote Controller - PQWRHQ0FDB
2
AC Smart 5 - PACS5A000
ACP 5 - PACP5A000
LonWorks Gateway - PLNWKB100
AC Smart IV BACnet - PBACNA000
ACP IV BACnet Gateway - PQNFB17C2
Dry Contact (1 contact, 24 VAC external power) - PDRYCB100
Dry Contact for Third Party Thermostat - PDRYCB300
Dry Contact for (2 setpoints) - PDRYCB400
Remote Temperature Button Sensor - ZRTBS01
Auxiliary Heat Relay Kit - PRARH1
Wi-Fi Module - PWFMDD200
24,000
Multi F Ceiling-Concealed High-Static Duct
ø1/2
ø3/8
ø5/8
58.6
1
27,000
37 / 35 / 34
ø1/4
SB_MultiF_HighStaticDucted_LHN248HV_2019_08_27_143456
777 / 706 / 636
0.59
LHN248HV
24,000 Btu/h Indoor Unit
71.9
1.6
0.24