Multi F Engineering Manual

Model Name LAN090HSV5 LAN120HSV5 LAN180HSV5
Nominal Cooling Capacity (Btu/h)
1
9,000 12,000 18,000
Nominal Heating Capacity (Btu/h)
1
10,900 13,600 21,600
Operating Range
&RROLQJ):%
57-77
Heating (°F DB)
59-81
)DQ
Type
Cross Flow
0RWRU2XWSXW:[4W\
30 x 1 60.0 x 1
Motor/Drive
Brushless Digitally Controlled / Direct
Airflow Rate CFM (H/M/L)
268 / 218 / 169 282 / 233 / 177 558 / 438 / 353
Unit Data
Refrigerant Type
2
R410A
Refrigerant Control
EEV
Power Supply V, Ø, Hz
3
208-230, 1, 60
Rated Amps (A)
0.4
Sound Pressure Level dB(A) (H/M/L)
4
36 / 32 / 27 38 / 34 / 29 44 / 38 / 34
'LPHQVLRQV:[+['LQ
32-15/16 x 12-1/8 x 7-9/16 39-9/32 x 13-19/32 x 8-11/32
1HW8QLW:HLJKWOEV
20.5 29.8
6KLSSLQJ:HLJKWOEV
25.6 36.4
3RZHU:LULQJ&RPPXQLFDWLRQV&DEOH
1R[$:*
5
4 x 18
Heat Exchanger
(Row x Column x Fin / inch) x Number
(2 x 23 x 22) x 1 (2 x 16 x 20) x 1
3LSH6L]H
Liquid (in.)
1/4
Vapor (in.)
3/8 1/2
Connection Size
Liquid (in.)
1/4 3/8
Vapor (in.)
3/8 5/8
Drain O.D. / I.D. (in.)
27/32, 5/8
1
Nominal capacity is rated 0 ft. above sea level with corresponding refrigerant piping length in
accordance with standard length of each outdoor unit and a 0 ft. level difference between outdoor and
indoor units. All capacities are net with a combination ratio between 95 – 105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF
ZHWEXOE:%DQGRXWGRRUDPELHQWFRQGLWLRQVRI)GU\EXOE'%DQG)ZHWEXOE:%
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF
ZHWEXOE:%DQGRXWGRRUDPELHQWFRQGLWLRQVRI)GU\EXOE'%DQG)ZHWEXOE:%
2
This unit comes with a dry helium charge.
3
$FFHSWDEOHRSHUDWLQJYROWDJH99
4
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the
same in both cooling and heating mode. These values can increase due to ambient conditions during
operation.
5
$OOSRZHUZLULQJFRPPXQLFDWLRQVFDEOHWRWKH,'8VEHPLQLPXP$:*FRQGXFWRUVWUDQGHG
shielded or unshielded (if shielded, must be grounded to chassis at ODU only) and must comply with
applicable local and national codes.
ART COOL MIRROR INDOOR UNITS
*HQHUDO'DWD6SHFL¿FDWLRQV
7DEOH Multi F Art Cool Mirror Indoor Unit General Data.
ART COOL MIRROR | 11