User manual

21
NO
NO
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO
PWB ASSEMBLY
PWB ASSEMBLY
1
2
Replace the sensor
(pressure).
Replace the PWB
Assembly.
Repair drain hose
Remove foreign
material.
Reconnect or repair the
connector
Replace the pump
assembly
Replace the PWB
Checking voltage between two pins as press
the power button is the voltage 220-240V~?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected,
disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160)
When checking voltage between connectors
(
, )on spinning, is the voltage
220 - 240V~ as the figure?
When pressing [Spin] and [Temp.] at the
same time after draining, is the water level
frequency 252 or more?
When pressing [Spin]
[Temp.] buttons at the
same time while wash, is the water level
frequency between 230 - 245V~?
HEATING WITHOUT WATER
DRAIN MALFUNCTIONING