- LG - Life's Good Air Conditioner User Manual

Operation Details
- 74 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
2. Operation Details
DISPLAY
(1) High quality LCD remote controller supplied
Operation Indicator
On while in appliance operation, off while in appliance pause
Timer(on/off) and Sleep timer Indicator
On while in timer mode (on/off) and in sleep timer mode, off when timer mode is completed or canceled
Defrost Indicator
Off except when hot start during heating mode operation or while in defrost control.
Plasma Indicator
On while in plasma mode, off while plasma mode is canceled.
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
If your want to use this operation, press the Auto Restart Button.
Power(Forced Operation)
Operation starts, when this button is pressed and stops when you press the button again.
Cooling Mode Operation
When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan
stop.
When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp=> Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp-0.5°C
While in compressor running, operating with the airflow speed set by the remote controller. While in com-
pressor not running, operating with the low airflow speed regardless of the setting.
Function of Controls