User's Manual Part 3

STAREX-IS BSM Manual
Page:540(877)
Issue:1.
0
SMD-011-PMA210
##NOK - BAMA NO RESPONSE
##NOK - ACU or REC NO RESPONSE
##NOK - UNKNOWN REASON
##OK - SET ACU TIME COMPLETED
4.8.4.5. Temperature Set Command
This is the command to set the temperature (high/low/middle)s threshold value of
which the environment monitoring module takes control. If the temperature surpasses
the set threshold value, the alarm is generating.
Command SET-ENV-TEMP:
[BSC=a],[BTS=b],[HI_TEMP=c],[LOW_TEMP=d],[MID_TEMP=e];
a : BSC Number(0 ~ 11)
b : BTS Number(0 ~ 47)
c : High Temperature(0 ~ 200)
d : Low Temperature(-20 ~ 200)
e : Middle Temperature(-20 ~ 200)
Input SET-ENV-TEMP:
Display
a : Locate Information
b : ##PROC_NOT_EQUIP
##PROC_ABNORMAL
##THIS COMMAND IS IN SERVICE
##NOK - BTS TYPE MISMATCH
##NOK - BAMA ABNORMAL
##NOK - ACU ABNORMAL
##NOK - RECTIFIER ABNORMAL
##NOK - BAMA NO RESPONSE
##NOK - ACU or REC NO RESPONSE
##NOK - UNKNOWN REASON
##OK - SET ACU TEMPERATURE COMPLETED
MSC(0x00) date time
M8034 SET ACU ALARM VALUE TEMPERATURE(HIGH/LOW/MIDDLE)
LOCATE = a
RESEON = b