Instructions / Assembly
Electronic Countdown Timer Switch
Cat. Nos. DT230, DT260, DT202, DT204, DT212 Lighted
Ratings: 20 A Resistive/16 A Inductive, 1,800 W Incandescent/Halogen, 600 W LED/CFL,
1,200 VA ELV/MLV/Flourescent, 1 HP or 16 A Motor/Fan, 120 VAC, 60 Hz - Single-Pole, 3-Way/Multi-Way
INSTALLATION INSTRUCTIONS
ENGLISH
PK-A3461-10-00-2A
WARNINGS:
•
TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a
receptacle, or a load in excess of the specied rating.
• DO NOT use to control lighting if it is the only light source in the area.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
Installation
WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn OFF power at circuit
breaker or fuse and test that the power is OFF before wiring!
1. Identify your wires (most common shown).
NOTE: A Neutral wire is required for operation. If the wiring in the wallbox
does not resemble this conguration, consult an electrician.
You Will Need:
• Slotted/Phillips screwdriver
• Electrical tape
• Cutters
• Pliers
Features
• Easy operation with four preset buttons and one "OFF" button.
• Simple press and hold override function for 24-hour override.
• For Single-Pole, 3-Way, Multi-Way, and Multi-Timer wiring.
• Zero Cross turn-ON technology that extends the life of the switching relays
(turns ON at the minimum voltage).
• You can attach up to nine (9) DD0SR-1Z Switch Companions and up to four
(4) DD0SR-DLZ Switch Companions to this Electronic Countdown
Timer Switch.
• Color change kits are available in white, light almond, ivory, black, brown, and
gray (DTKIT-00x).
•
Available with ve countdown timer options (30 and 60 minutes, and 2, 4, 12 hours)
.
• Available in a 15A single-pole timer (Cat. No. DT1xx).
3. Test and mount.
• Restore power. Wait 20 seconds for the timer to power up.
NOTE: The bottom green LED blinks once every 5 seconds during power up.
• Press any timer button to turn the load ON.
NOTE: If load does not turn ON, refer to the "What to do if..." section.
• Turn OFF power at circuit breaker before completing the installation.
• Gently push wires into wallbox. Use the screws to attach timer to wallbox.
• Install wallplate.
• Restore power.
Single Pole
LINE
LOAD
From
Branch Circuit
NEUTRAL
GROUND
To Load
Switch Wallbox
Timer Wallbox
LINE
TRAVELER 1
NEUTRAL
TRAVELER 2
LOAD
TRAVELER 1
TRAVELER 2
GROUND
From
Branch Circuit
To Timer
Wallbox
To Load
From Switch
Wallbox
NEUTRAL
GROUND
3-Way
NOTE: Timer must be installed in the same location as the load wire.
2. Wire device.
Work on one connection at a time, and connect the wires as shown.
DO NOT remove
the insulating label.
Single Pole
TRAVELER
(Yellow/Red)
LOAD
(Blue)
LOAD
LINE
NEUTRAL
GROUND
GROUND
(Green)
From
Branch Circuit
To Load
GROUND
GREEN
LINE
BLACK
3-WAY
YELLOW/RED
LOAD
BLUE
NEUTRAL
WHITE
NEUTRAL
(White)
LINE
(Black)
DD0SR-1Z
Switch Companion
DT2xx
Timer
To Load
From
Switch Companion
GROUND
GROUND
(Green)
TRAVELER
(Yellow/Red)
LOAD
TRAVELER 2
TRAVELER 1
LOAD
(Blue)
GROUND
From
Branch Circuit
NEUTRAL
NEUTRAL
(White)
NEUTRAL
LINE
TRAVELER 2
TRAVELER 1
To Timer
GROUND
GREEN
LINE
BLACK
3-WAY
YELLOW/RED
LOAD
BLUE
NEUTRAL
WHITE
LINE
(Black)
3-Way Wiring with DD0SR-DLZ Switch Companion
3-Way Wiring with DD0SR-01Z Switch Companion
3-Way Wiring with Two Timers (DT2xx)
Timer 1
LINE
Timer 2
To Load
From Timer 1
GROUND
TRAVELER
(Yellow/Red)
LOAD
TRAVELER 1
(Yellow/Red)
TRAVELER 2
TRAVELER 1
TRAVELER 1
TRAVELER 2
LOAD
(Blue)
LOAD
(Blue)
GROUND
(Green)
To Timer 2
GROUND
From
Branch Circuit
NEUTRAL
(White)
NEUTRAL
NEUTRAL
(White)
NEUTRAL
GROUND
GREEN
LINE
BLACK
3-WAY
YELLOW/RED
LOA
D
BLUE
NEUTRAL
WHITE
LINE
(Black)
GROUND
GREEN
LINE
BLACK
3-WAY
YELLOW/RED
LOAD
BLUE
NEUTRAL
WHITE
LINE
(Black)
DD0SR-DLZ
Switch Companion
DT2xx
Timer
To Load
From
Switch Companion
GROUND
GROUND
(Green)
TRAVELER
(Yellow/Red)
LOAD
TRAVELER 2
TRAVELER 1
LOAD
(Blue)
GROUND
From
Branch Circuit
NEUTRAL
NEUTRAL
(White)
NEUTRAL
LINE
TRAVELER 2
TRAVELER 1
To Timer
GROUND
GREEN
LINE
BLACK
3-WAY
YELLOW/RED
LOAD
BLUE
N
EUTRAL
WHITE
LINE
(Black)
DO NOT remove
the insulating label.
CAUTIONS:
• DO NOT use disinfecting products, including foggers, sprays or other types of atomized
cleaning agents.
• DO NOT spray liquid onto the product.
• To clean, use a damp cloth with mild soap.
• No user serviceable components. DO NOT attempt to service or repair.
• Use this device WITH COPPER OR COPPER-CLAD WIRE ONLY.
WEB VERSION