Troubleshooting and fault elimination
Display Cause Remedy
MASTER DAMAGED!
The EPM in the MASTER PORT is
defective.
Press the menu key to return to the
main menu.
Plug an EPM in the MASTER PORT.
The EPM is not placed correctly in the
MASTER PORT.
The message does not indicate an
error but only serves as a note.
The message is only displayed for a
short time.
MASTER MISSING
Seen on power-up if there is no EPM
in the MASTER PORT.
Information only.
Programmer is trying to read data
from the MASTER PORT but cannot
detect an EPM in this PORT.
Insert a valid EPM into the MASTER
PORT.
INVALID MASTER!
The EPM you are attempting to read in
the MASTER PORT is defective or has
no valid data.
Press the menu key now to return to
the main menu.
Exchange the EPM in the MASTER
PORT.
The EPM in the MASTER PORT is a
Configuration EPM.
A Configuration EPM cannot be
copied.
NAME EXISTS!
The file name you want to allocate to a
parameter file already exists.
Select another file name.
MEMORY FULL
The internal memory of the EPM
programmer is full.
It is not possible to save any more
parameter files.
If necessary, delete parameter files
you do not need anymore.
TRANSFER FAILED
Error in the data transmission to the
EPM PORT, because the memory chip
is defective, or is not placed correctly
in the PORT.
Exchange the defective EPM or plug
the EPM correctly in the PORT.
Attempted MASTER -> EPM transfer
when- the memory size of the
MASTER EPM is different from that
of the target.
Replace the EPM in the EPM PORT
with an EPM of the same color as
the Master.
Error in the data transmission to the
EPM PORT, because of an internal
error in the EPM programmer.
Please contact your Lenze
representative.
INVALID OPTION!
Attempted to CREATE a new file from
a servo drive EPM in the MASTER
PORT.
Only inverter drive EPM’s can be
saved as files in the EPM Programmer.
INVALID EPM!
Attempted to EDIT a non-servo EPM
or a corrupted servo EPM.
Replace the EPM in the EPM PORT
with a valid servo EPM.
NO FILES
Attempting to EDIT, DELETE or
CREATE a file, but there are no stored
files in the EPM Programmer.
CFG EPM MISSING!
Attempt to LOAD CFG EPM without
a valid configuration EPM in the
MASTER PORT.
Insert a configuration EPM into the
MASTER PORT.