Owner manual

Commissioning
Possible settings via DIP switch
7
EDK94AYCDN DE/EN/FR/ES/IT 3.0
41
H1inbet−bevor
7 Commissioning
Possible settings via DIP switch
E94YCDN001D
Via the DIP switches on the front, the following can be set:
ƒ Station address using switches 1 ... 32 ("MAC ID" area)
ƒ Baud rate using switches 1 and 2 ("Baud" area)
Pos.
Switch positions
Baud rate Node address (MAC ID)
2 1 kbps 32 16 8 4 2 1
S225
OFF
OFF 125 The station address results from the sum of the
binary values of switches 1 ... 32.
l Example: Station address 44
switches 32, 8, 4 = ON (32 + 8 + 4 = 44)
l Valid address range: 0  63
l The Lenze setting for all switches is OFF.
OFF ON 250
ON OFF 500
ON ON No function
Note!
Please observe the information about the setting of the DIP switches given in
the "Commissioning" and "Appendix" chapters of the E94AYCDN
communication manual (DeviceNet).