Instruction Manual

Wiring the device
Wiring
Wiring of control connections
5
57
EDK94PNE245 DE/EN/FR/ES/IT 2.0
5.3.4 Wiring of control connections
24 V supply
Terminal X11 Labelling Description
GE GND external supply
24E 24 V external supply through safely separated power supply unit
(SELV/PELV)
IEC 61131−2, 19.2 ... 28.8 V, residual ripple max. ±5 %
Current during operation: 1.4 A
Starting current: 4 A for 100 ms
9400SSP000X2
SB Reserved
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm
Digital inputs, digital outputs
Terminal X12 Labelling Description
GOI GND digital out / in
DI1 Activation of brake chopper
(external 24 V supply required)
DO1 Mains OK
DO2 Brake chopper active
DO3 Short circuit in brake chopper
SSP9400X12
DO4 Heatsink overtemperature
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.2 ... 2.5
24 ... 12 Spring terminal
With wire end
ferrule
Stripping length / contact length: 10 mm