Instruction Manual
EDS84DMOTECAT EN 2.1 - 11/2012 L 65
Communication manual 8400 motec EtherCAT®
Error messages
Possible causes and remedies
Operational status quit [0x01bc8131]
Response (Lenze setting printed in bold) Setting: C13880/1 (; Adjustable response)
: No response ; Error Fault ; Warning locked
Cause Remedy
The EtherCAT data exchange was stopped in the
"Operational" state.
• See also chapter "Interruption of EtherCAT
communication" ( 56).
• Check cables and terminals.
• Connect network cable to EtherCAT terminals.
• The master has to reset the node to the "Operational"
status. (If required, check a pending emergency
message first).