DiagnosticErrorCodeFRU/Action
018-250-XXXPCICardServiceserror1.PCIcard
2.Risercard,ifinstalled
3.Systemboard
020-000-XXXPCIInterfaceTestPassed
Noaction
020-0XX-XXXPCIInterfaceerror1.PCIcard
2.Risercard,ifinstalled
3.Systemboard
020-195-XXXPCITestabortedbyuser
InformationonlyRe-startthetest,ifnecessary
020-196-XXXPCItesthalt,errorthresholdexceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
020-197-XXXPCItestwarning
1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6"Using
theSetupUtility"onpage39
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
020-198-XXXPCItestaborted
1.Ifacomponentiscalledout,makesureitis
connectedand/orenabled.SeeChapter6"Using
theSetupUtility"onpage39
2.Flashthesystemandre-test.See"Flashupdate
procedures"onpage467
3.Goto"Undeterminedproblems"onpage65
020-199-XXXPCItestfailed,causeunknown1.Goto"Undeterminedproblems"onpage65
2.Flashthesystemandre-test.See"Flashupdate
procedures"onpage467
3.Replacecomponentunderfunctiontest
020-262-XXXPCIsystemerror1.PCIcard
2.Risercard,ifinstalled
3.Systemboard
025-000-XXXIDEinterfaceTestPassed
Noaction
025-00X-XXX025-01X-XXXIDEinterfacefailure
1.IDEsignalcable
2.Checkpowersupplyvoltages
3.ReseatIDEsignalcable
4.IDEdevice
5.Systemboard
025-027-XXXIDEinterfaceConguration/Setuperror
1.IDEsignalcable
2.Flashthesystem.See"Flashupdateprocedures"on
page467
3.ReseatIDEsignalcable
4.IDEdevice
5.Systemboard
Chapter7Symptom-to-FRUIndex53