Instructions / Assembly

Water Service Fittings and Curb Stops:
Pack Joint end connections
Application:
This information is applicable to Models T-5300, T-5300MP, T-4211, T-4300, T-4320, T-4305, T-4326, T-
4301, T-4321, T-4325, T-4410, T-4412, T-4411, T-4413, T-4440, T-4441, T-4442, T-4110, T-4111, T-4112, T-
4500 and T-4501. For other models, please see the installation-operation-maintenance sheets for ring
compression connections or flared connections. They can be downloaded at www.legendvalve.com or by
calling Customer Service at 800-752-2082. Legend pack joint curb stops and fittings are designed and
manufactured in accordance with AWWA C-800 specifications and are suitable for installation onto
underground cold water service lines only.
NOTE: All pack joint end connections accept the following CTS (Copper Tubing Size) types of tubing or IPS
(Iron Pipe Size) types of pipe:
CTS tubing:
Types K or L copper tubing
CTS polyethylene plastic tubing (ASTM D2737 SDR9)
IPS pipe:
Steel pipe
Brass pipe
PVC pipe (ASTM D1785-06)
IPS polyethylene plastic pipe (ASTM D2239 SIDR 7)
Extra-strong (XS) lead pipe (models T-4110, T-4111 and T-4112 only)
Insert stiffeners (sold separately) MUST be used when installing fittings or curb stops onto polyethylene plastic
tubing or pipe.
Installation Instructions for pack joint end connections:
1. Cut tubing or pipe to desired length, using an appropriate tubing or pipe cutter.
2. The cut must be square and round. Correct any out-of-round tubing or pipe using the appropriate tool.
The cut end of the tubing or pipe must be free of burrs, dents, nicks, deep scratches, dirt or debris.
3. If you are installing the Legend pack joint fitting or curb stop onto polyethylene plastic tubing or
pipe, insert the correct stiffener into the cut end of the plastic tubing or pipe (Legend Model T-4500 or
T-4501). Make sure to fully insert the stiffener. Partially inserted stiffeners may prevent the pack joint
connection from joining or sealing correctly. NOTE: Insert stiffeners are not required when installing
rigid PVC plastic pipe or metallic tubing or pipe.
4. Remove the pack joint nut assembly from the fitting or curb stop body.
5. Visually verify that the assembly is complete: pack joint nut, stainless steel clamp bolt, NBR rubber
gasket and Nylon anti-friction ring (underneath the gasket). (insert pack-joint nut exploded view
diagram here)
6. Place the pack joint nut assembly over the end of the tubing or pipe, clamp end first. Make sure the anti-
friction ring and gasket are not cocked at an angle. Both should be resting flat against the inside face of
the pack joint nut.
7. Slide the pack joint nut assembly down onto the tubing or pipe approximately three inches.