Installation Instructions

LZW36 | Fan & Light Switch
Red Si
www.inovelli.com/lzw36/setup contact@inovelli.com page 8
NOTE: If you’d like to verify if the switch is within range of your Z-Wave hub before installing the canopy module, feel free to turn the
power back on. The switch should light up and run through a series of colors before finally turning blue. Once the switch LED bars
are blue, hold down the top of Button A and Button B for 5 seconds and the switch LEDs will turn Green. Release the buttons and if
the switch LED’s remain Green, then the switch is within Z-Wave range. If the LED bars turn Red, then the switch is not within range.
Step 2: Installing the Fan Canopy Module
Materials Needed: Wire nuts, screwdriver, access to a neutral (white), load (black), fan and light wires and the included zip-tie.
Ensure the distance between your fan switch and module is no more than 32.8ft (10m) as that is the
maximum distance the RF signal can travel from the switch to the canopy module.
Remove your ceiling fan from the electrical box and identify the load (black -- which is now hot),
neutral (white), and the fan motor and light loads (usually red is the fan and blue is the light, but your
wires may be dierent).
Connect the wires together as shown on Page 7 or as shown in Figure 1.1.
Once completed, it’s time to check to make sure everything works and is paired correctly. Please
fasten the canopy to the fan bracket using the included zip-tie (as shown on page 7), ensure all
connections are secure with no exposed copper and re-assemble your fan.
Step 3: Pairing the Switch to the Canopy Module
Now that everything is installed, and your fan is re-assembled it’s time to pair the switch to the canopy module.
NOTE: The fan module should be paired to the Z-wave switch from the factory. In case you have an issue,
below is how you can manually do so. Warning: Do not try to test the fan without it being secured to the ceiling.
With the fan secured to the ceiling and the switch secured to the wall, let’s start the pairing process of the switch and module.
To pair the switch to the module, apply power from the circuit breaker to both devices. Note: After trying to pair to the Z-Wave switch for 30 seconds, if not
successful, the fan module goes into pairing mode for 2 minutes. You can tell it is in this mode by the bulb in thexture pulsing.
Press and hold Button D and press Button E 3x. If successful, the LED bar will blink Green.
You should now be able to control the fan speed and light brightness from the switch manually. Press Buttons B & E
to turn the fan and light on and o, and hold up and down Buttons A & D to change the fan speed and light dim level.
Step 4: Pairing the Switch to Your Hub/Gateway
Now that your switch and canopy module are paired, it’s time to pair your switch to your Z-Wave enabled hub or gateway.
Enable the inclusion process on your Hub or Gateway.
Hold down button A and press button B 3x quickly and your LED Bars will pulse blue signifying the
switch is in inclusion mode. If successful, the switch LED Bars will flash Green and if unsuccessful, the
LED Bars will flash Red.
If the LED Bars flash Red, please check your Z-Wave signal by referencing the Note at the top of the page.
If your switch is within range, you may want to try an exclusion. Instructions are to the right.
Switch (Local) Configuration Mode
There are a couple dierent ways you can set the configuration parameters of your switch (listed on page 9). It is recommended that you
set them from your hub when possible, but if not, you can set them directly from the switch! For more detailed instructions, please check our
support webpage at support.inovelli.com. Here are some basic instructions:
Enter into either light configuration mode or fan configuration mode based on which parameters you want to edit. Light: Hold down the A
Button + B Button for 10 Seconds. Fan Hold down the D Button + E Button for 10 Seconds.
Press either the light on/o button (B) or the fan on/o button (E) the number of times that corresponds with the parameter you want
to change (listed on page 9).
Use the light level up/down (A) or fan level up/down (D) buttons to set the parameter to the number you would like. Each press
increments the value by 1.
The LED on the switch will flash yellow to show you which parameter number you are editing. The LED will also flash purple to show you
the value that you have assigned. A long flash represents 10s and a short flash represents 1s. So, for example, two long flashes followed by
three short flashes would represent 23.
After you are finished, press and hold JUST the B or E button (depending on whether you are editing the light or fan configuration) for 10
seconds to save and exit.
1.
2.
3.
4.
5.
Figure 1.1
Having Problems
Including? Try an
Exclusion
Place your hub or gateway
into exclusion mode. Then:
Hold button A + Press
Button B 3x. If it is
successful the LED will
blink green.
Then, try including again.
Avertissement: N’essayez pas de tester le ventilateur sans qu’il soit fixé au plafond.