Quick Setup Manual

Z-Wave Network
Z-Wave can be used with a few devices or it can be used to build a large network. Below you’ll see two examples. In the rst
example, a user has a Gateway which is looking for Z-Wave devices within its radius. Z-Wave devices outside this radius will not be
found and need to either be moved within the radius or use a repeating device to reach it. The second example shows how a
repeater can be used to reach a device outside of the initial radius. Keep this in mind when building your own network and make
sure to use the range estimator below.
LT-3200 Switch LT-3200 Switch LT-3200 Switch
NOTE: Z-Wave range will never be a perfect circle due to walls, furniture, etc. The above is for reference only.
Wiring Instructions
Please do not try installing this device if you are unsure of how electrical circuits operate within your home.
Technology upgrades can be exciting, but they can also be dangerous when not installed correctly.
LT-3200 Switch LT-3200 Switch
LT-3200 Switch LT-3200 Switch LT-3200 SwitchLT-3200 Switch
Material Thickness
Signal
Depreciation
Aerated Concrete Stone < 30cm // 11.8” 20%
Aluminum Coating < 1mm // 0.04” 100%
Ceiling < 30cm // 11.8” 70%
Furniture [Non-wood] < 30cm // 11.8” 40-60%
Glass [No Metal Coating] < 5cm // 2.0” 10%
Inner Wall < 30cm // 11.8” 40%
Iron Reinforced Concrete < 30cm // 11.8” 30-90%
Metal Grid < 1mm // 0.04” 90%
Outer Wall < 30cm // 11.8” 60%
Plaster < 10cm // 3.9” 10%
Pumice < 30cm // 11.8” 10%
Red Brick < 30cm // 11.8” 35%
Stone < 30cm // 11.8” 30%
Wood < 30cm // 11.8” 40-60%
LT-3200 Switch
Wiring Instructions: Neutral Installation
Please use this if you have a neutral wire, typically white, in the installation area. For non-neutral installations or wiring
congurations that use Traveler terminals of the LT-3200, more wiring diagrams and information are available within the
product manual found at: https://urcportal.com/resources-total-control/
Thank you for purchasing the URC LT-3200 Switch!
This quick setup manual will help you plan and install your Z-Wave
lighting solution.
!
This device is intended for
installation in accordance with the
National Electric Code and local
regulations in the United States, or
the Canadian Electrical Code and
local regulations in Canada.
Risk of Fire
Risk of Electrical Shock
Risk of Burns
Risque d’incendie
Risque de choc électrique
Risque de brûlures
Please DO NOT use this switch
to control Medical or Life Support
equipment.
TURN OFF THE POWER to the
circuit for the switch and lighting
xture at the circuit breaker prior to
installation. Wiring live connections
can and will result in injury while
also damaging the device.
The metal plates surrounding
the switch assembly are a heat
sink. Max load rating of 600W is
applicable when installed in a
single gang-box with all six (6)
tabs still intact.
PLEASE NOTE: URC is unable to provide electrical and/or wiring advice outside of this document. If you are unable
or unsure, please contact an electrician.
! !
!!
! !
!! ! !
!!
Z-Wave Command Classes
5E - COMMAND_CLASS_ZWAVEPLUS_INFO
26 - COMMAND_CLASS_SWITCH_BINARY
70 - COMMAND_CLASS_CONFIGURATION
85 - COMMAND_CLASS_ASSOCIATION
59 - COMMAND_CLASS_ASSOCIATION_GRP_INFO
55 - COMMAND_CLASS_TRANSPORT_SERVICE
86 - COMMAND_CLASS_VERSION
72 - COMMAND_CLASS_MANUFACTURER_SPECIFIC
5A - COMMAND_CLASS_DEVICE_RESET_LOCALLY
73 - COMMAND_CLASS_POWERLEVEL
98 - COMMAND_CLASS_SECURITY
9F - COMMAND_CLASS_SECURITY_2
5B - COMMAND_CLASS_CENTRAL_SCENE
6C - COMMAND_CLASS_SUPERVISION
32 - COMMAND_CLASS_METER
75 - COMMAND_CLASS_PROTECTION
22 - COMMAND_CLASS_APPLICATION_STATUS
7A - COMMAND_CLASS_FIRMWARE_UPDATE_MD
Warranty
Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be free from defects in material and workmanship under
normal usage for one (1) year from purchase for all products with the exception of all Total Control® whole-house products which is for two
(2) years from purchase, when such is purchased from URC. This limited warranty is valid only in the United States of America. URC warrants
that the software will substantially conform in any material respect to its functional specications at the time of delivery. URC shall not be
liable for operational, technical or editorial errors and/or omissions made in the URC documentation. URC does not warrant that the URC
software is bug-free or error free or that there are no errors/bugs in the URC software.URC equipment purchased from other than an
authorized URC dealer or distributor are without warranty.In the event of any warranty claim, URC will, at its sole option, repair the URC
equipment using new or comparable rebuilt parts, or exchange the URC equipment for new or rebuilt equipment. In the event of a defect,
these are the end user’s exclusive remedies. All the URC equipment returned for service, exchange or repair require an RGA number. To obtain
an RGA number, you must complete a Return Request Form which you may obtain by calling (914) 835-4484 or contacting URC at
returnrequest@urc-automation.com. To obtain warranty service, end user must deliver the URC equipment, freight prepaid, in its original
packaging or packaging affording adequate protection to URC at 37 Ramland Road, Unit 104, Orangeburg, NY 10962. It is end user’s
responsibility to backup any macro programming, artwork, software or other materials that may have been programmed into the unit. It is
likely that such data, software, or other materials will be lost during service and URC will not be responsible for any such damage or loss. A
dated purchase receipt, bill of sale, installation contract or other veriable proof of purchase is required.For detailed information regarding
warranties and returns, please visit URC’s website available at
http://www.urc-automation.com/warranty or call the Customer Service Center at (914) 835-4484.
This switch is designed for use only with
permanently installed xtures. To install multiple
switches, remove the tabs as needed.
Unlike the LT-3100 Dimmer, the heat sink tabs are
not used and have no effect on performance.
Ce gradateur est conçu pour être utilisé
uniquement avec des luminaires installés en
permanence. Pour installer plusieurs gradateurs,
supprimez les onglets si nécessaire.
Contrairement au LT-3100 Dimmer, les languettes
du dissipateur de chaleur ne sont pas utilisées et
n'ont aucun effet sur les performances.
Parameter
#
Change at
the Switch?
About Description Range Default
Size
(Bytes)
1 Yes Power On State
Default power state the switch will revert to after power loss. (0 - Return
to State | 1 - On | 2 - Off)
0,1,2 0 1
2 Yes Invert Switch Inverts the switch. (0 - Disabled | 1 - Enabled) 0,1 0 1
3 No Auto Off Timer Automatically turns the switch off after X amount of seconds. 0-32767s 0 1
4 No
Association
Behavior
Sets when the switch should send commands to an associated device. (01 -
Local | 02 - 3-way | 03 - 3-way & Local | 04 - Z-Wave Hub | 05 - Z-Wave
Hub & Local | 06 - Z-Wave Hub & 3-way | 07 - Z-Wave Hub & Local & 3-
Way | 08 - Timer | 09 - Timer & Local | 10 - Timer & 3-Way | 11 - Timer & 3-
Way & Local | 12 - Timer & Z-Wave Hub | 13 - Timer & Z-Wave Hub & Local
| 14 - Timer & Z-Wave Hub & 3 -Way | 15 - All)
01-15 15 1
5 Yes LED Indicator Color Sets the default color of the LED Bar. 0-255 160 2
6 Yes
LED Indicator
Intensity
Sets the intensity of the LED Bar. (0 - Off | 1 - Low | 5 - Med | 10 - High) 0-10 3 1
7 Yes
LED Indicator
Intensity (When Off)
Intensity of the LED Bar when the switch is off. (0 - Off | 1 - Low | 5 - Med |
10 - High)
0-10 1 1
8 No LED Indicator Effect Allows the LED Bar to perform different effects as notications.
Use URC
Tool
0 4
10 No
Active Power
Reports
Sends a report when power levels raise or drop below the assigned value.
(0 - Disabled | 10 - 10% of prev report | 100 - 100% of prev report)
0, 1-
100%
10 1
11 No
Periodic Power &
Energy Reports
Period of time before a report can be sent after a report was already
generated.
0-32767s 3600 2
12 No Energy Reports
Sends a report when energy levels raise or drop below the assigned value.
(0 - Disabled | 10 - 10% of prev report | 100 - 100% of prev report)
0, 1-
100%
10 1
13 No
Load Type
Adjustment
Can be used for dumb switch setups. (0 - Detect Type | 1 - Manually
Set Type)
0,1 0 2
51 No Instant On
There is a delay that allows for multi-tap scene control. (0 - No Delay |
1 - Delay)
0,1 1 1
!
Association Groups
Group 1: Lifeline
Members of this group will receive unsolicited
messages related to the status of the switch.
Group 2: Basic Setup
Sends start and stop level change to
associated devices.
Grouping Identier Max Nodes Send Commands
Group 1 0x05
Central Scene Notication
Basic Report
Device Reset Locally
Protection Report
Group 2 0x05 Basic Set
Resetting Your Device
You may hold the Cong Button (A) for 20 seconds or use a certied controller to remove the device from your network to factory
default. Only use this procedure in the event that the network primary controller is missing or inoperable.
Single-Pole Installation (Single Switch)
3-Way Installation (Line/Load in Separate Boxes)
The LT-3200 can be used in a 3-way/4-way lighting installation.
The Master Load Controller must be dened in URC software.
Secondary controllers must be dened in URC software.
Multi-Way will not work without prior programming.
Traveler Wire is not needed for Multi-Way congurations of
two or more LT-3200s.
Load
Line/Hot
Neutral
Traveler
Romex Cable
D
B
A
C
A. Config Button: This button is used to enter the conguration menu on your switch. When you hold it
down for 10-15 seconds, the LED Bar (B) will light up Yellow to indicate you are in cong mode. It
can also be used to trigger a favorite scene. After setting up the scene, tap the button one time to
trigger it.
B. RGB LED Notification Bar: This LED bar serves as a visual display for whether your lights are on or
off and offers visual notications based on events that are setup via the Gateway. It can be further
congured, disabling or setting certain brightness levels.
C. Responsive Paddle: The paddle works in a similar manner to a standard switch. Pressing up will
turn the light on while pressing down will turn the light off. The switch can be tapped up or down 1-5
times to trigger a specic scene.
D. Air Gap Switch: This will cut the power to the load your switch is wired to.
Including A Switch
Below are the steps for including (pairing) a switch to a Gateway.
LT-3200 Switch
Plan, Prep, and Install:
Locate an area to install the switch that is within a recommend distance from the Gateway.
Walls, ceilings, and even furniture may degrade communication between devices.
Remember to turn off the power prior to installation.
Check the signal range by holding the cong button for 5-10 seconds. [ Green = Good Signal / Red = Poor Signal ]
Including to the Network:
Start the inclusion process from the programming software.
Once started, press the cong button on the switch three times and the LED Bar will ash blue. If included
successfully, the bar will turn green. If it turns red, the inclusion process failed.
Switch Not Including? Try an Exclusion:
Start the exclusion process from the programming software.
Once started, press the cong button on the switch three times. The LED Bar will turn Green if excluded successfully.
B
A
Switch Configuration Settings
There are a couple of ways to congure a switch. The rst is via the switch itself, while the second is via the
programming software.
Parameter #
# Of Config Button
Presses
About Description
1 1 Power On State Default power state the switch will revert to after power loss.
2 2 Invert Switch Inverts the switch.
5 3 LED Indicator Color Sets the default color of the LED Bar.
6 4 LED Indicator Intensity Sets the intensity of the LED Bar.
7 5 LED Indicator Intensity (When Off) Intensity of the LED Bar when the switch is off.
Configuration Logic
Toenter conguration mode, hold down the Config Button (A) for 10-15 seconds and the
LED Bar (B) will light up yellow.
Once your parameter has been selected, the LED Bar (B) will blink yellow. Now press up or
down on the paddle to adjust the parameter settings to your liking.
Finally, once you’ve settled on a customization, it’s time to save the conguration settings.
Hold the Config Button (A)for 10 seconds and the LED Bar (B) will then blink to conrm the
settings were saved.
CAUTION - PLEASE READ!
OTHER WARNINGS
SHOCK HAZARD
MULTIPLE SWITCHES
MAX WATTAGE KEY
MEDICAL EQUIPMENT
APPLIANCES AND MOTORS
1
4
5
6
2
3
Use two or more LT-3200s for the
best possible user experience.
!!
URC RECOMMENDATION
Cet appareil est destiné à être
installé conformément au National
Electric Code et aux réglementations
locales des États-Unis, ou au Code
canadien de l'électricité et aux
réglementations locales au Canada.
COUPEZ L'ALIMENTATION du circuit
pour le gradateur et le luminaire du
disjoncteur avant l'installation. Le
câblage des connexions en direct peut
entraîner et entraînera des blessures tout
en endommageant l'appareil.
Les plaques métalliques entourant
l'ensemble gradateur sont un dissipateur
de chaleur. L'indice de charge maximal
de 600W est applicable lorsqu'il est
installé dans une seule boîte de gang
avec les six (6) onglets encore intacts.
S'il vous plaît NE PAS utiliser ce
gradateur pour contrôler l'équipement
médical ou de survie.
Switch Parameters
About Description
Config Button
LED Effect LED Color Duration
Press / Hold # Press / Sec
Clear Notications Clears the RGB Bar of any notications. Press 2x N/A N/A N/A
Inclusion / Exclusion 3x Tap of Cong Button (30s timeout) Press 3x Pulse Blue (Default) See desc
Disable Internal Relay Disables the internal relay. Press 8x Fast Blink Red 3x Blink
Enable Internal Relay Enables the internal relay. Press 8x Fast Blink Green 3x Blink
Z-Wave Signal Test Tests the signal strength of the switch. Hold 5-10s Solid Green N/A
Parameter Conguration Change the parameters from the switch. Hold 10-15s Solid Yellow N/A
Factory Reset Factory reset the switch. Hold 20s Solid Red 3x Blink
Config Button Command Features
This product can be operated in any Z-Wave network with other Z-
Wave certied devices from other manufacturers. All mains
operated nodes within the network will act as repeaters regardless
of vendor to increase reliability of the network.
SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave
QR Code present on the product with a controller providing SmartStart inclusion. No further
action is required and the SmartStart product will be added automatically within 10 minutes
of being switched on in the network vicinity.
Security 2 DSK
The DSK can be found on the front of the switch (metal plate) and inside the box.
Specifications
Power: 120V AC / 60Hz
Signal (Frequency): 908.42 MHz
Operating Temperature Range: 32-104 °F (0-40 °C)
Maximum Load: 600W Incandescent / 300W LED / 150 CFL
Approval: UL Listed / FCC / IC / Z-Wave Plus Certified / CAN ICES-
003 (B) / NMB-003(B)
For indoor use. Specications subject to change without notice due
to continuing product improvement.
To reduce the risk of overheating and
possible damage to equipment, DO
NOT attempt to control a receptacle,
motor driven device, a uorescent
light xture, or an appliance.
Pour réduire le risque de surchauffe et
d'endommagement possible de l'équipement,
N'essayez PAS de contrôler un réceptacle,
un dispositif à moteur, un appareil d'éclairage
uorescent ou un appareil.

Summary of content (1 pages)