User's Manual

Compact Portable Receiver
Rio Rancho, NM
13
and UT300.
EU Dig. Hybrid works with Lectrosonics European
Digital Hybrid transmitters with model numbers that
end in “/E01. For example, the SMDB/E01 transmitter
is in this group.
JA Dig. Hybrid works with Lectrosonics Japanese
Digital Hybrid transmitters.
4a) Find a Clear Frequency with Smart Tune
TM
Optimum range will be realized if the system is set
to a frequency where few or no other RF signals are
present (a “clear” frequency). The receiver can select a
clear frequency automatically with Smart Tune
TM
.
Navigate to Smart Tune in the LCD menu and press
MENU/SEL to start the process. Select the desired
range to be scanned, then press MENU/SEL to start
the scan.
Entire tuning range
Individual block(NA) North American
versions
NOTE: “NA” next to the band numbers indicates
the North American version which excludes the
radio astronomy frequency allocation from 608 to
614 MHz.
Cursor scrolls
across screen
during scanning
When the scan is complete a screen will appear briefly
to display the frequency chosen by Smart Tune, and
then it will change to IR Sync. If you are using a Lec-
trosonics transmitter that has an IR port, the settings
can be transferred from the receiver to the transmitter
in a few seconds with a single button.
As shown below, IR Sync will prompt you to place
the receiver and transmitter close to one another and
press the UP arrow button. Hold the units within two
feet or so apart with the IR ports facing each other,
then press the button. The transmitter LCD will display
a message confirming the receipt of the settings.
NOTE: IR sync transfers the settings for
frequency, step size and compatibility mode.
If you are not using a Lectrosonics transmitter with an
IR port, simply return to the Main Window and observe
the frequency that was chosen by Smart Tune. Make
sure the compatibility mode selected in the receiver is
correct for the transmitter in use. Then set the transmit-
ter on the frequency chosen by Smart Tune.
4b) Find a Clear Frequency Manually
Navigate to RF Scan on the menu and press MENU/
SEL to start the scanning. The LCD will display a
marker that travels across the screen as a graphical
image of the RF energy appears. The marker will wrap
back to the beginning and continue to repeat.
Clear
spectrum
Strong RF
energy