Datasheet
UMAREX GmbH & Co. KG
.
Donnerfeld 2
.
59757 Arnsberg
.
Germany
.
Tel. +49 2932 638-300
.
Fax +49 2932 638-333
.
laserliner@umarex.de
.
www.laserliner.com
Rev.0211
Cable tracer set with transmitter
and receiver
AC-Tracer
including carrying case
+ transmitter TX
+ receiver RECV
+ Euro connector
+ UK plug
+ E 27 Lamp adapter
+ battery
Packing dimension (W x H x D)
330 x 210 x 70 mm
TECHNICAL DATA
TRANSMITTER AC-TRACER TX
POWER SUPPLY
200-240V AC, 50-60 Hz
OVERVOLTAGE CATEGORY
CAT III 300V, pollution degree 2
DIMENSIONS (W x H x D)
50 x 80 x 32 mm
WEIGHT 54 g
RECEIVER AC-TRACER RECV
MEASURING RANGE
0...5 cm measuring depth
POWER SUPPLY
1 x 9V block, IEC LR6, Alkali
DIMENSIONS (W x H x D)
68 x 165 x 36 mm
WEIGHT (incl. battery) 155 g
AC-Tracer
– Non-contact tracing of the transmission
signal by the receiver
– Fast tracing of coherent electrical circuits
– Location of lines in coherent, live electrical circuits
– Detection of fuse circuits in live installations
– Receiver with audible signal tone for locating
measured objects
– Transmitter power supply directly from power
cable to be tested = measurement under
operating conditions
– Receiver with adjustable sensitivity for optimum
fine adjustment
– Socket adapter for direct and fast testing
in building installations
– E27 lamp adapter for direct and fast testing
in lamp circuits
Adjustable sensitivity Various connection options
ARTICLE ARTICLE NO EAN-CODE PU
AC-Tracer 083.050A 4 021563 672103 5