Data Sheet

Table Of Contents
RM1xx LoRa/BLE Modules
Datasheet
https://connectivity.lairdtech.com/wireless-
modules/lorawan-solutions
36
© Copyright 2019 Laird. All Rights Reserved
Americas: +1-800-492-2320
Europe: +44-1628-858-940
Hong Kong: +852 2923 0610
Integration instructions for host product manufacturers
Applicable FCC rules to module
FCC Part 15.247 / FCC Part 15.249
Summarize the specific operational use conditions
The module is must be installed in mobile device.
This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and
2) The transmitter module may not be co-located with any other transmitter or antenna
As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible
for testing their end-product for any additional compliance requirements required with this module installed.
IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location
with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final
product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the
transmitter) and obtaining a separate FCC authorization. The OEM integrator has to be aware not to provide information to the end
user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module.
The end user manual shall include all required regulatory information/warning as show in this manual.
Limited module procedures
Not applicable
Trace antenna designs
Not applicable
RF exposure considerations
30mm separation distance and co-located issue shall be met as mentioned in “Summarize the specific operational use conditions”.
Product manufacturer shall provide below text in end-product manual
“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator & your body.”
Antennas
Brand name Model name Antenna type Antenna gain Antenna connector
WP WPANT10009-S3A
Dipole
2
IPX MHF
Label and Compliance Information
Product manufacturers need to provide a physical or e-label stating
“Contains FCC ID: SQG-RM191” with finished product
Information on Test Modes and Additional Testing Requirements
Test tool: 2.4G : UW TerninalX v1.01 & LoRa : proprietary LoRa Hopping test demo script shall be used to set the module to