Install Instructions
Table Of Contents
- Cover
- Table of Contents
- SECTION 1 Product Accessories
- SECTION 2 Product Characteristics
- SECTION 3 Safety Regulations
- SECTION 4 Installation
- 4.1 Location and Clearances
- 4.2 Wall Mount Bracket
- 4.3 Combustion Air
- 4.4 Venting, Exhaust
- 4.5 General Location Guideline
- 4.6 Locations for Vent Pipe Terminator
- 4.7 Air Supply and Vent Connections
- 4.8 Vent / Air Pipe Termination
- 4.9 Gas Supply and Piping
- 4.10 Gas Supply Pressure
- 4.11 Gas Setup and Adjustment
- 4.12 High Altitude Installations. 2,000’ to 10,000’
- 4.13 Natural Gas to Propane Conversion
- 4.14 Plumbing Guidelines
- 4.14 Plumbing Guidelines
- 4.15 Pressure Relief Valve
- 4.16 Disposal of Condensate
- 4.17 Electrical Wiring Connections
- 4.18 DIP Switches
- 4.19 Control Board, Electrical Diagram
- 4.20 Ladder Diagram
- 4.21 Electrical Connections
- SECTION 5 Control Display and Operation
- SECTION 6 Error Codes
- SECTION 7 Trouble Shooting
- SECTION 8 Maintenance
- SECTION 9 Installation Check
- SECTION 10 Parts
- Notes:
Page 50
4.18 DIP Switches
System Control Setting
DIP switches 6 and 7 have to be set in the OFF position when the boiler is running normally.
DIP switches 1, 2, and 3 are system switches and are factory set to the boiler model and size
and should not be touched.
Maximum ame detecting voltage 2.4V
Pre-purge time Tp Maximum 10s, minimum 1s
Safety Time (igniting time) Ts 1.5s
Igniting interval time 10s
Post-purge time Tip 120S (1st : 60s + 2nd 60s)
Over-heating 1,2,3 protection detection time <2s
High & Low Water Level detection time <5s
High & Low Water Level Recover time <5s
Temperature sensor anomaly detection time <3s
APS sensor detection time <3s
800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors)
20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 (Applications Engineering)
1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130
www.Laars.com
Document 4296D
The FT Series, Heating Only, Gas Conversion Kit
pg 3 of 4
Table B DIP Switch Settings
MBH 80 100 120 140 N/A 199
These 3 bottom switches must be set per unit SIZE.
9.
Per Table B, set DIP Switch
5 to OFF
for LP Propane.
10.
Turn ON the GAS and WATER supply to the FT.
11.
Turn ON the FT.
12.
Connect a manometer to the manifold pressure port. For dual port manometers, use the positive pressure
side. Check for proper manifold gas pressure. Refer to Table C.
ON OFF
MIN Fire Normal Operation
MAX Fire Normal Operation
NG Natural LP Propane
3” Vent Size
2” Vent Size
ON OFF ON OFF ON
ON
OFF ON ON OFF OFF
ON
OFF OFF OFF ON ON
ON
Figure D
Gas Valve for 80 to 140 MBH
Gas Valve for
199 MBH
The gas valve on
the smaller models is
mounted vertically.
Manifold Pressure Port
Manifold Pressure Port
Table C
Manifold pressure Propane Gas (LP) Natural Gas (NG)
MFTHW 80/100
-0.102
˝
WC -0.102
˝
WC
0.00
˝
WC 0.00
˝
WC
MFTHW 120/140
-0.216
˝
WC -0.216
˝
WC
0.00
˝
WC 0.00
˝
WC
MFTHW 175
-0.169
˝
WC -0.129
˝
WC
-0.015
˝
WC -0.015
˝
WC
MFTHW 199
-0.173WC -0.134
˝
WC
-0.015
˝
WC -0.015
˝
WC
CO
2
value
Propane Gas (LP) Natural Gas (NG)
2˝ VENT 3˝ VENT 2˝ VENT 3˝ VENT
MFTHW 80/100
120/140/175/199
9.5~11% 8.5~10.5%
9~10.5 % 8~10%
Refer to the below table.
Manifold pressure Propane Gas (LP) Natural Gas (NG)
MFTHW 80/100
-0.102
˝
WC -0.102
˝
WC
0.00
˝
WC 0.00
˝
WC
MFTHW 120/140
-0.216
˝
WC -0.216
˝
WC
0.00
˝
WC 0.00
˝
WC
MFTHW 175
-0.169
˝
WC -0.129
˝
WC
-0.015
˝
WC -0.015
˝
WC
MFTHW 199
-0.173WC -0.134
˝
WC
-0.015
˝
WC -0.015
˝
WC
CO
2
value
Propane Gas (LP) Natural Gas (NG)
2˝ VENT 3˝ VENT 2˝ VENT 3˝ VENT
MFTHW 80/100
120/140/175/199
9.5~11% 8.5~10.5%
9~10.5 % 8~10%
Refer to the below table.
13.
Establish a call for heat. You may need to disconnect the outdoor reset if you are making this gas
conversion during warm weather.
Shown is a
Model 140
with 3"
Venting and using
Natural Gas