User's Manual

10.0 Exiting the Heavy Weather program
To close the “Heavy Weather” software, simply click on the “Exit” icon
11.0 Technical Data
The following information provides an overview of the technical data of the weather station.
Outdoor data
Transmission Distance in Open Field : 82ft max.
Outdoor Temperature Range : -21.8ºF to +157.8ºF (show “OFL” if outside range)
Resolution : 0.2ºF
Measuring Range Rel. Humidity : 20% to 95% (if the relative humidity is less than 20% or greater
than 95%, it will display 19% or 96%)
Resolution : 1%
Rain Volume Display : 0 to 39.37 inch (1h and 24h rainfall)
0 to 98.38 inch (Total rainfall)
Resolution : 0.01 inch
Wind Speed : 0 to 111.8mph
Resolution : 0.1mph
Wind Direction : Graphic resolution 22.5 Degrees, Numerical Resolution, Letter
format
433MHz transmission:
Measuring interval thermo-hygro sensor : 32 seconds (
if wind factor22.36 mph
) or 128seconds (
if wind factor<
22.36mph
)
10 minutes (if the base station fails to receive any data after 5
attempts in a row; all outdoor data readings will display “---“,
except for the rain value)
With wire data transmission:
Measuring interval thermo-hygro sensor : 8 seconds