12. COOLING SYSTEM
12-15
YUP 25 0
THERMOSENSOR
THERMOSENSOR REMOVAL
Remove the met-in box and center cover.
Drain the coolant.
Disconnect the thermosensor wire.
Remove the thermosensor.
THERMOSENSOR INSPECTION
Suspend the thermosensor in a pan of water
over a burner and measure the resistance
through the sensor as the water heats up.
Temperature(
)
50
80
100
120
Resistance(W)
154
52
27
16
THERMOSENSOR INSTALLATION
Apply 3-BOND No. 1212 sealant or
equivalent to the thermosensor threads and
install it into the thermostat housing.
Connect the thermosensor wire.
Fill the radiator with coolant. (
!
3-9)
Install the center cover (
!
2-7) and met-in
box. (
!
2-6)
Be sure to bleed air from the cooling
system.
Thermosensor
Thermosensor Wire
Thermosensor
Thermometer
Thermosensor
Thermosensor Wire