Brochure

THE INDUSTRY’S SMALLEST COMMERCIAL/INDUSTRIAL PORTABLE AIR CONDITIONER
KPAC II
COOLING CAPACITY
Model KPAC II 14 Model KPAC II 18 Model KPAC II 24
BTU/hr @ 95 F at 60%RH13,700 (1.1 TON) 16,800 (1.5 TON) 22,900 (2 TON)
COMPRESSOR DATA
Compressor Type HERMETIC ROTARYHERMETIC ROTARY
HERMETIC ROTARY
Operating Temperatures70-100F 50% RH70-100F 50% RH70-100F 50% RH
Non-CFC Refrigerant Charge 410A 410A 410A
FAN DATA
EVAPORATOR
Fan Type DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE
Air Flow (CFM) 460/Single Speed 625/Single Speed 810/Single Speed
Supply Air Data2-5"Dia.x12"Length2-5"Dia.x12"Length2-6"Dia.x15"Length
Supply Duct Max. Length in Ft. 10 Ft. 15 Ft. 15 Ft.
CONDENSER
Fan Type DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE
Air Flow (CFM) 700825 1100
Condenser Duct Data (Optional) One -12-in. Dia.x 8' LengthOne -12-in. Dia.x 8' Length One -14-in. Dia.x 8' Length
Condenser Duct Max. Length in Ft.15-ft 15-ft25-ft
ELECTRICAL DATA
Power Supply (Volts/Amps)115-V/15-Amps - 1 Phase 115-V/20-Amps - 1 Phase 208/230-Single Phase
Current Consumption (Amps)11.514.510.6/9.6
Power Consumption (KW) 1.31.7 2.4
Maximum Circuit Breaker (Amps)152020
Minimum Circuit Ampacity (Amps)17.09 19.1712.15
Min/Max Voltage105
-125 105-125195-225/210-250
Power Cord Gauge/Length in Ft. 14 AWG/8-ft Length 12 AWG/8-ft Length 12AWG/7'
Plug Configuration NEMA 5-15NEMA 5-20 NEMA 6-20
DIMENSIONAL DATA
Width x Depth x Height (Inches) 16.25 x 26 x 37.2516.25 x 26 x 37.2520.25 x 29 x 44
Weight (Lbs.)155 157206
Shipping Weight (Lbs.)215 217266
Single Duct Ceiling Kit - CK-12S 22 22 26
Total Shipping Weight/w Kit 237242 292
SAFETY DEVICE DATA
Compressor Overload Internal Internal Internal
Fan Motor Overload Automatic Internal Automatic Internal Automatic Internal
Evaporator Freeze-up Freeze StatFreeze Stat Freeze Stat
High Pressure Switch Manual Manual Manual
Compressor Short Cycle YesYes Yes
Automatic Restart YesYes Yes
ThermostatMicroprocessor/DigitalMicroprocessor/Digital Microprocessor/Digital
Condensate Pump (w 20' Head) Optional Optional Optional
Condensate Tank Overflow YesYes Yes
M
o
d
e
l
KPAC II 1
8
16
,
800
(
1.5 TON
)
H
ERMETI
C
R
O
TAR
Y
7
0
-1
00
F 5
0
% R
H
41
0A
D
IRE
C
T DRIV
E
6
25
/
Sin
g
le Spee
d
2-5"Dia.x12"Len
g
t
h
5 Ft
D
IRE
C
T DRIV
E
8
2
5
One -12-in. Dia.x 8' Len
g
t
h
15-
ft
115-V
/
20-Amps - 1 Phas
e
14
.
5
1.7
2
0
1
9
.1
7
1
0
5-125
12 AWG
/
8-ft Len
g
t
h
N
EMA 5-2
0
1
6
.25 x 2
6
x 37.2
5
1
5
7
21
7
22
24
2
I
nterna
l
A
utomatic Interna
l
F
reeze Sta
t
M
anua
l
Y
e
s
Y
e
s
M
icroprocessor
/
Digita
l
Optiona
l
Ye
s
M
o
d
e
l
KPAC II 1
4
13
,
700
(
1.1 TON
)
H
ERMETI
C
R
O
TAR
Y
7
0
-1
00
F 5
0
% R
H
4
1
0A
D
IRE
C
T DRIV
E
4
60
/
Sin
g
le Spee
d
2-5"Dia.x12"Len
g
t
h
1
0
Ft
.
D
IRE
C
T DRIV
E
7
00
One -12-in. Dia.x 8' Len
g
t
h
15-
ft
115-V
/
15-Amps - 1 Phas
e
11
.5
1
.3
15
17.
09
1
0
5-125
14 AWG
/
8-ft Len
g
t
h
N
EMA 5-1
5
1
6
.25 x 2
6
x 37.2
5
1
5
5
21
5
22
23
7
I
nterna
l
A
utomatic Interna
l
F
reeze Sta
t
M
anua
l
Y
e
s
Y
e
s
M
icroprocessor
/
Digita
l
Optiona
l
Ye
s
M
o
d
e
l
KPAC II 2
4
22
,
900
(
2 TON
)
HERMETI
C
R
O
TAR
Y
7
0
-1
00
F 5
0
% R
H
41
0A
DIRE
C
T DRIV
E
810
/
Sin
g
le Spee
d
2-6"Dia.x15"Len
g
t
h
5 Ft
DIRE
C
T DRIV
E
11
00
One -14-in. Dia.x 8' Len
g
t
h
25-
f
t
208
/
230-Sin
g
le Phas
e
10.6
/
9.
6
2.4
2
0
12.1
5
195-225
/
210-25
0
12AWG
/
7
'
NEMA 6-2
0
2
0
.25 x 2
9
x 4
4
2
06
2
66
2
6
2
92
I
nterna
l
A
utomatic Interna
l
Freeze Sta
t
Manua
l
Y
e
s
Y
e
s
Microprocessor
/
Digita
l
Optiona
l
Ye
s