User Guide
7-11C
DYNAMIC GENERATOR VALUES 250-525 MXC, EXC RACING (KOKUSAN 4K-3B)
Measuring conditions:
–remove seat, side trim and left side cover
– all connectors and the ground connection in a non-corroding condition, connectors tightly connected
– battery in a startable condition, not fully loaded (start several times for fully loaded battery)
– start engine, the measurement must be taken right after starting
Regulator rectifier output – measure the voltage with the measuring
leads of the peak voltage adapter directly on the poles of the vehicle bat-
tery:
– Unstressed (no electric consumer switched on), engine running at idle
speed (1400 +/-50 rpm)
Multimeter display: 14 volts +/- 1 volt
– Stressed (light switched on, horn and brake actuated), engine running
at idle speed
Multimeter display: 12 volts +/- 1 volt
– Stressed (light switched on, horn and brake actuated), engine running
at increasing speed (up to 8000 rpm)
Multimeter display: 13 volts +/- 1 volt
NOTE: the black measuring lead on the peak voltage adapter should be
applied to the ground (negative terminal).
Check the charge current – remove main fuse, apply the multimeter
measuring leads (without the peak voltage adapter) to both connectors
on the fuse carrier
1 and measure the current (set the multimeter DCA
to 10 amperes):
– Unstressed (no electric consumer switched on), engine running at idle
speed
Multimeter display: 1.3 amperes +/- 0.1 ampere
– Stressed (light switched on, horn and brake actuated), engine running
at idle speed
Multimeter display: -0.6 amperes +/- 0.1 ampere
– Stressed (light switched on, horn and brake actuated), engine running
at increasing speed
Multimeter display: 0.0 amperes +/- 0.1 ampere
1