Installation & Assembly
6. Install the Control Amplifier
Power Supply
Grounded Outlet
Screws
Control Amplifier
Chromatherapy Connection
Status LED
Auxiliary-In Port
FRONT
Transducer Terminals
User Interface
Connection
Power Cable
BACK
WARNING: Risk of electric shock. Connect the control amplier to a properly grounded, grounding-type
receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do not
remov
e the grounding pin from the plug or use a grounding adapter.
IMPORTANT! Keep insulating materials away from the control amplier. Provide an unobstructed air space around the
control amplier to permit cooling.
NOTE: The control amplier can be positioned vertically or horizontally.
Install the mounting brackets to the control amplier
.
Position the control amplier ush or recessed from the front of the studs.
Using the wood screws provided, secure the control amplier to the framing. Use the anchors provided if securing to a
w
all material other than wood.
NOTE: The transducer terminals and wires are numbered to identify the correct connections. When required, the control
amplier can be removed to ease wire connection.
Securely aach the transducer wires to the transducer terminals on the control amplier
. The white with black wires
are the positive (+) leads, and the solid white wires are the negative (-) leads.
If equipped with chromatherapy, connect the chromatherapy connector to the chromatherapy terminal on the control
amplier
.
Connect the clear connector on the user interface cable to the control amplier user interface connection.
If used, connect the auxiliary-in connector to the auxiliary-in connection on the control amplier
.
Plug the power supply into the electrical outlet. Make sure that the other end of the power supply is connected to the
pow
er-in connection on the control amplier.