Installation Guide

Roughing-In
IMPORTANT! All dimensions are nominal. The tolerance of the stud pocket is +1/4 (6 mm) and -0 (0
mm). Carefully measure your fixture before determining enclosure size. When a fire-rated wall is specified,
dimensions are to the inside of the wall board. Some shimming between the stud frame and the fixture
may be required. Dimensions given in the roughing-in information are crucial for proper installation.
Construct the framing and plumbing accurately.
NOTE: If a firewall is required, increase the roughing-in dimensions of the unit according to the thickness
of the firewall material. Dimension of the stud pocket must take into account the thickness of the firewall
material and may need to be adjusted.
NOTE: If the unit will be installed against a masonry wall, make provisions for plumbing connections.
Construct a separate frame wall a minimum of 6 (15.2 cm) from the masonry wall.
7-11/16"
(19.5 cm)
2-5/8"
(6.7 cm)
1-3/8"
(3.5 cm)
9-15/16"
(25.2 cm)
Cover Detail
Flange Detail
Cover
Location
K-9396,K-9397,K-9479
36" (91.4 cm)
K-9393 42" (106.7 cm)
K-9394 48" (121.9 cm)
K-9395 60" (152.4 cm)
K-9396 36" (91.4 cm)
K-9393 42" (106.7 cm)
K-9394,K-9397 48" (121.9 cm)
K-9395, K-9479 60" (152.4 cm)
K-9396 18" (45.7 cm)
K-9393 21" (53.3 cm)
K-9394,K-9397 24" (61 cm)
K-9395, K-9479 30" (76.2 cm)
K-9396,K-9397, K-9479
37-3/8" (94.9 cm)
K-9393 43-3/8" (110.2 cm)
K-9394 49-3/8" (125.4 cm)
K-9395 61-3/8" (155.9 cm)
2-5/16" (5.9 cm)
3-11/16"
(9.4 cm)
1-5/16"
(3.3 cm)
K-9396, K-9397, K-9479
18-13/16" (47.8 cm)
K-9393 21-13/16" (55.4 cm)
K-9394 24-13/16" (63 cm)
K-9395 30-13/16" (78.3 cm)
K-9396,K-9397, K-9479 3/8" (1 cm)
K-9393, K-9394, K-9395 1/2" (1.3 cm)