Installation Guide
3. Install Electrical Outlet – United States and Canada
WARNING: Risk of electric shock. Connect the power supply to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the plug grounding pin. Do not use a grounding adapter.
Your bath with heated surface is equipped with a cord and plug. The power supply has been wired
at the factory. A qualified electrician must install a GFCI-protected, 120 V, 15 A, grounded outlet.
Locate the outlet behind the bath and within 24″ (610 mm) of the power supply.
For -2MW Music Models: Refer to the installation instructions included with the amplifier for
wiring and installation details. Position the amplifier anywhere within the shroud (not
recommended) or in a remote location. If installed within the shroud, the amplifier will need to
remain plugged into the electrical outlet at all times.
Plug the power cord into this outlet.
GFCI-Protected
Receptacle
Power Supply
User
Keypad
Heated
Surface
1196030-2-C 6 Kohler Co.