Installation Guide
6. Install Electrical Outlets – United States and Canada
WARNING: Risk of electric shock. Disconnect the power before performing the following
procedures.
NOTE: For installations in Latin America, go to the ″Make Electrical Connections – Latin America″
section.
NOTICE: The control amplifier and junction box are each equipped with a cord and plug. A qualified
electrician must install two GFCI- or RCD-protected, 120 V, 15 A grounded outlets. Both outlets may share
the same electrical service, but no other load should be on this circuit.
Install a 120 V, 15 A grounded outlet within the wall framing and within 24″ (610 mm) of the
planned control amplifier location. Route the wires through conduit for this outlet installation.
Install a 120 V, 15 A grounded outlet near the control board end of the bath and within 24″ (610
mm) of the junction box.
Control
Amplifier
24" (610 mm)
Maximum
Conduit
Junction
Box
24" (610 mm)
Maximum
120 V, 15 A
Grounded Outlet
120 V, 15 A
Grounded Outlet
Conduit
Control
Board
1212244-2-B 8 Kohler Co.