9.11
Section 9
Disassembly
9
Figure 9-40. Removing B+ Charging Lead from
Connector.
4. Remove the stator and rectifier-regulator.
Remove Cam Pulley and Coolant Pump
Belt
1. Remove the hex. flange screw and flat washer,
securing the cogged drive pulley to the camshaft.
See Figure 9-41.
Figure 9-41. Removing Cam Pulley Mounting
Hardware.
2. Lift the pulley off the camshaft and work the belt
off the coolant pump pulley. See Figure 9-42.
Figure 9-42. Removing Cam Pulley and Belt.
3. Remove the camshaft key from the keyway.
Remove Water Pump and Transfer Tube
1. Unseat the clamp and disconnect the by-pass hose
from the water pump fitting. See Figure 9-43.
Figure 9-43. Removing By-pass Hose from Water