7. Install the Strike Jamb and Strike Seal
CAUTION: Risk of product damage.It is critical the provided spacers are re-installed in the
configuration shown in the attached view. If the spacers are not reinstalled, metal-to-glass contact
will result. The glass will shatter then the handle is tightened.
Position the latch in the strike jamb.
Using the 5/64 hex wrench provided, tighten the two screws to secure the latch in place.
Repeat with the second latch.
Push the strike jamb into the appropriate wall jamb with the wide lip facing toward the inside of
the shower. Each slot in the strike jamb will slide over the screw body and fit between the clamp
and wall jamb.
Secure the strike jamb to the wall jamb at the top and bottom by tightening the flathead screws with
the 3/32 hex wrench until snug.
Install a strike jamb cover on the top opening of the strike jamb.
Use scissors or a utility knife to cut any excess bulb seal away so the seal is flush with the top of
the strike jamb.
Slide the strike seal strip into the T-slot of the strike jamb until the seal touches the bottom track.
With a utility knife, trim the excess seal so the seal is flush with the top of the strike jamb.
Latch
Strike Jamb
Wall Jamb
#6-20 x 1/2"
Screw
Bottom View
Strike Jamb Cover
Top View
Adjustment Clamp
Wall Jamb
Flathead Screw
Strike Jamb
Strike Seal
Kohler Co. 11 1036565-2-D