Installation Guide

Installation Sequence
IMPORTANT! Several included components will be powered by the control amplifier via 25’ (7.6 m)
cables. Plan the control amplifier location so the cables will reach without being under tension.
For best results, follow the installation sequence below. Detailed instructions are found on the following
pages of this guide.
The illustration above shows a typical installation with the preferred user interface and control amplifier
locations. Depending upon your bath the installation will be similar.
Recommended Installation Sequence
Determine the locations for the bath components. Refer to the illustration for preferred locations.
Determine the location for the access panel required for servicing the control amplifier.
NOTICE: Use wood studs to construct the bath frame. Metal framing may adversely affect the
vibracoustic quality of the product.
Construct the framing for your bath.
Install the rough deck material.
Route the plumbing supply and drain lines for the bath.
Install the bath and drain.
Route the transducer wires to the control amplifier location.
Install an electrical outlet within 24 (610 mm) of the area chosen for the control amplifier.
If equipped, route the chromatherapy cable to the area chosen for the control amplifier.
Route the user interface cable from the control amplifier area to the user interface location.
Install the control amplifier.
Connect the transducer, user interface, optional auxiliary device (if utilized), and chromatherapy
cable (if equipped) to the control amplifier.
Finish the walls and deck, and install the required access panel for the control amplifier.
24" (610 mm)
User Interface
6" (152 mm) Maximum
Control Amplifier
Access Panel
Transducer
Wires
Chromatherapy Cable
(If Equipped)
10"
(254 mm)
User Interface
Cable
Power Supply
Control
Amplifier
Cable
Kohler Co. 5 1297608-2-B